User`s guide
DataBase
Event Filter 
31
1. Choose System, Setup, Event Filter. Then 
click on the Add New Icon. 
Event Filters
 can be defined to prevent unwanted activity from being displayed at this workstation. 
Each Filter can determine which Locations, readers, inputs, and outputs will generate events that are 
visible at this workstation. Event Filters are defined locally for each workstation that is to employ 
them. When no filters are defined, all events from all locations are displayed at that Workstation.
Multiple Event Filters
 can be defined for each Workstation with each one controlled by a time zone. 
This allows a Workstation on the LAN to view card read events and/or alarm activity, from one area 
during one part of the day, from an additional area during another specified time of day, and possibly 
from all areas during yet another period of time.
When using multiple Event Filters at a Workstation it is important to consider that each filter is in 
parallel with the next. If it is desired to block a particular event then each filter must block that event 
or it will be visible in the Workstation program.