6- IMPORTANT SAFETY INFORMATION
6.1 Fire prevention:
-Never locate the fixture on any flammable surface.
-Minimum distance from flammable materials: 1,5 MT.
-Minimum distance from the closest illuminable surface: 0,5 MT.
-Replace any blown or damaged fuses only with those of identical value.
Refer to the wiring diagram if there is any doubt.
-Connect the projector to mains power via a thermal magnetic circuit breaker.
6.2 Prevention of electric shock:
-High voltage is present inside the unit. Unplug the unit prior to performing any function which involves
touching the inside of the moving head.
-The level of technology inherent in the ZOOM requires the assistance of specialised
personnel for all servicing. Please refer to an authorised DTS service centre.
-A good earth connection is essential for proper functioning of the projector.
-Never connect the unit without proper earth connection.
-The fixture should be located in places with a good air ventilation.
6.3 Safety:
-The projector should always be installed with bolts, clamps and other tools that are capable of
supporting the weight of the unit.
-Always use a second safety cable to sustain the weight of the unit in case of the failure of the main
fixing point.
-The external surface of the unit, at various points, may exceed 70°C.
Never handle the unit until at least 10 minutes have elapsed since the
projector was turned off.
-Never install the fixture in an enclosed area lacking sufficient air flow. The ambient temperature should
not exceed 40°C.
6.4 Level of protection against the penetration of solid and liquid objects:
-The projector is classified as an ordinary appliance and its protection level against the penetration of
solid and liquid objects is IP 20.
For outdoor use, D.T.S. reccomend the use of the dedicated raincovers:
DELTA 10 R
• Rain cover for XR base (top) (cod. 03.MA001)
• Rain cover for XR base (bottom) (cod. 03.MA002)
ARC 1200
0,5M
8
F
!
!
DELTA 10 R ZOOM