DELTA R DELTA R FULL COLOR DELTA R TRILED DELTA 5-7 RGB R GB User’s Manual Rel 1.5 D.T.S. Illuminazione srl - ITALY http://www.dts-lighting.
DELTA R Le informazioni contenute in questo documento sono state attentamente redatte e controllate. Tuttavia non è assunta alcuna responsabilità per eventuali inesattezze. Tutti i diritti sono riservati e questo documento non può essere copiato, fotocopiato, riprodotto per intero o in parte senza previo consenso scritto della D.T.S . DTS si riserva il diritto di apportare senza preavviso cambiamenti e modifiche estetiche , funzionali o di design a ciascun proprio prodotto. D.T.
DELTA R 3 INDEX: 1- TECHNICAL FEATURES 2- IMPORTANT SAFETY INFORMATION 4 8 2.1 Fire prevention 2.2 Prevention of electric shock 2.3 Protection against direct light radiation 2.4 Safety 2.5 Level of protection against the penetration of solid and liquid matter 3- VOLTAGE AND FREQUENCY 4- INSTALLATION 9 9 4.1 Safety cable 4.2 Risk of fire 4.3 Ambient temperature 5- MAINS CONNECTION 10 5.1 Protection: 6- DMX SIGNAL CONNECTION 10 6.1 DMX Addresses 6.
DELTA R 1- TECHNICAL FEATURES Delta R Full Color 40 RGB Full Color LEDs/ LED power 3W 2.800 Lumens / 370 Lux at 5 m (medium flood lenses) RGB color generation / 16 million colours Colour temperature variable on a linear range (3.200°K÷5.500°K) No infrared emission / no ultraviolet emission LEDs average lifespan: 100.
DELTA R Delta R Triled 20 LEDs / TRILED technology / LED power 1W x 3 2.400 Lumens / 450 Lux at 5 m (medium flood lenses) RGB color generation / 16 million colours Colour temperature variable on a linear range (3.200°K÷5.500°K) No infrared emission / no ultraviolet emission LEDs average lifespan: 100.
DELTA R 1- TECHNICAL FEATURES Delta 5 RGB R 108 X 1W Luxeon type LEDS (36 Red, 36 Green, 36 Blue) 2.400 Lumens / 900 Lux at 5 m (medium flood lenses) RGB color generation / 16 million colours Colour temperature variable on a linear range (3.200°K÷5.500°K) No infrared emission / no ultraviolet emission LEDs average lifespan: 100.
DELTA R 1- TECHNICAL FEATURES Delta 7 RGB R 108 X 1W P4 type LEDS (36 Red, 36 Green, 36 Blue) 2.400 Lumens / 1150 Lux at 5 m (medium flood lenses) RGB color generation / 16 million colours Colour temperature variable on a linear range (3.200°K÷5.500°K) No infrared emission / no ultraviolet emission LEDs average lifespan: 100.
DELTA R 2- IMPORTANT SAFETY INFORMATION 2.1 Fire prevention: -Never locate the fixture on any flammable surface. -Minimum distance from flammable materials: 1 m. -Minimum distance from the closest illuminable surface: 1 m. -Replace any blown or damaged fuses only with those of identical value. Refer to the wiring diagram if there is any doubt. -Connect the projector to mains power via a thermal magnetic circuit breaker. 2.2 Prevention of electric shock: -High voltage is present inside the unit.
DELTA R . 3- VOLTAGE AND FREQUENCY: Delta R can operate at 90-270V, 50 or 60 Hz. 4- INSTALLATION: Delta R may be either floor or ceiling mounted. For floor mounting installations, the unit is supplied with four rubber mounting feet on the base. For ceiling mounted installations, we reccommend the use of appropriate clamps to fix the unit to the mounting surface.
DELTA R 10 4.3 Ambient temperature: The projector should never be installed in places that lack a constant air flow. The ambient temperature should NOT exceed 40°C. 5- MAINS CONNECTION: Delta R can operate at 90-270V, 50 or 60Hz. For connection purposes, ensure that your plug can handle at least 300W power consuption. Strict adherence to regulatory norms is strongly Recommended. MAINS Electronic ballast 90-260V 50 / 60Hz FUSE: T 3,15A 5.
DELTA R 11 6.1 DMX Addresses: DELTA R have 15 DMX control channels. Here below are described the DMX channels addressing for the controller: Projector Projector Projector ….. projector 1 2 3 6 A001 A016 If you want to select the next projector, just add “15” A031 A…. A091 6.2 Selelcting the DMX address: 1) Press the UP-DOWN key until you reach the required DMX address. The numbers on the display will start to flash (but the new DMX address hasn't yet been set). 2) Press ENTER to confirm your selection.
DELTA R 12 8- DISPLAY FUNCTIONS DISPLAY FUNCTIONS The DELTA R display panel shows all the available functions . Using these functions, it is possible to change some of the parameters and add some functions. Changing the DTS setting can vary the functions of the unit so that it does not respond to the DMX 512 used to control it. Carefully follow the instructions below before carrying out any variations or selections. DELTA SOFTWARE RELEASE 1.
DELTA R 13 1)GLOBAL SETTING MENU LANGUAGE DEFAULT PAGE SECURITY DEFAULT SETTING SET DATE SET TIME UPDATE DOWNLOAD ABOUT A001 Up-Down GLOBAL SETTING Menu Up-Down Language ENTER LANGUAGE SELECTION This menu allow to set the Up-Down Default Page Security Up-Down Set Language English English = Default Set Default Page Four Digit = DMX address visualisation ENTER Status = DMX / Color Mode / Boost Power / Security ENTER ENTER Up-Down ENTER DEFAULT PAGE SELECTION This menu allow to set the v
Up-Down Set Time ENTER Up-Down TIME SETTING This menu allow to set the unit’s on board clock for STAND ALONE MODE Up-Down Update ENTER Up-Down DELTA R Real time internal clock setting Set Time Hour 03 Minute 01 Select UPDATE Mode Direct to PC UPDATE MENU This menu allow to upgrade the uni’s software by computer or remote control ENTER Update the unit’s software from PC by cable ENTER Download the unit’s program to PC by cable ENTER ENTER to CONFIRM Up-Down Download ENTER Up-Down
DELTA R 15 2)MODE SETTING MENU MODE MODE MODE MODE MODE MODE MODE DMX RECORDER MASTER SLAVE IR MANUAL TWILIGHT A001 Up-Down MODE SETTINGS Menu Up-Down Mode DMX ENTER ENTER Up-Down DMX ADDRESS SELECTION This menu allow to set the unit’s DMX address. Up-Down Mode Recorder Set Address DMX Address range 001-489 ENTER 001 ENTER Up-Down RECORDER MODE SETTING This menu let you create 2 different chases,CPR1 and CPR2 (16 steps each) that will then run in Master Mode.
Up-Down Mode Master ENTER Up-Down MASTER MODE SETTING This menu allow to set Delta R as master unit (No DMX signal must be present on unit’s DMX input panel) . The unit will ran in automatic mode without needing of an external controller. Different chases are selectable by user Set MASTER MODE Mode : Actual : MASTER DMX Up-Down Master Mode Set CHASE Set TIME Set WAIT CPR1 Sec 0025 Sec 0015 CRNB Rainbow colours effect.
DELTA R 17 Up-Down Mode IR Set IR MODE ENTER Up-Down Mode : Actual : IR MODE SETTING By activating IR mode on Delta unit it will be possible to navigate trought the unit functions by using the D.T.S. infrared remote control (D.T.S. Code :0514L008). IR DMX The unit is controlled by the infrared remote control ENTER ENTER to CONFIRM INFRARED REMOTE CONTROL ON/OFF Button By activating IR mode on Delta unit it will be possible to navigate trought the unit functions by using the D.T.S.
DELTA R 18 Up-Down TWILIGHT MODE ENTER Up-Down TWILIGHT MODE MENU This menu allow to set the unit in Twilight mode. Twilight mode let you turn ON and OFF the unit at a specific clock time (including day of the week) and/or at a specific twilight level. The Twilight mode make use of a twilight sensor located on the front panel near unit display. To know the twilight ambient level value measured from the sensor, scroll the unit menu till MEASURE Mode and select Twilight.
DELTA R 19 A001 Up-Down MOVING HEAD SETUP Menu Up-Down Pan Min ENTER ENTER Up-Down PAN MINIMUM POSITION This menu allow to set the Pan minimum position (Default =000) Up-Down Pan Max Tilt Min ENTER Up-Down Tilt Max ENTER Up-Down Calibrate Pan ENTER Up-Down Calibrate Tilt TILT CALIBRATION This menu allow to calibrate Tilt home position (Default = 128) Setting Tilt Min Setting Tilt Max Tilt Max : 000 Calibrating Pan ENTER Up-Down PAN CALIBRATION This menu allow to calibrate Pan home
DELTA R 20 Up-Down Invert Pan ENTER Up-Down PAN INVERTION This menu allow to set the Pan movement. Normal or Inverted Up-Down Invert Tilt ENTER Up-Down TILT INVERTION This menu allow to set the Tilt movement. Normal or Inverted Up-Down Swap Pan&Tilt ENTER Up-Down PAN&TILT SWAP This menu allow to invert the control of Pan with the control of Tilt.
DELTA R 21 4)LED SETUP MENU COLOUR MODE WHITE BALANCE BOOST DRIVING MIN RGB MAX RGB SMOOT FILTER PWM FREQUENCY A001 Up-Down LED SETUP Menu Up-Down Colour Mode ENTER ENTER Up-Down COLOUR MODE This menu allow to select the LED’S colour mode control system between RGB, CMYK or HSV Set Colour Mode RGB CMYK HSV Actual RGB RGB Mode (Default) Ch7 = Dimmer / Ch8 = Red Ch9= Green / Ch10= BLue ENTER CMYK Mode Ch7 = Black / Ch8 = Cyan Ch9= Magenta / Ch10= Yellow HSV Mode Ch7 = Nu / Ch8 = Hue Ch9= Satura
DELTA R 22 Up-Down Set Smooth Filter Smooth Filter ENTER Up-Down SMOOTH FILTER VALUE This menu allow to select the value of the delay( in millisecons) for RGB channels reaction to DMX or Program variation. 001=2.
DELTA R 23 6)MEASURE MENU LIFE DMX VOLTAGE TEMPERATURE TWILIGHT A001 Up-Down Life MEASURE MENU Menu Up-Down ENTER LIFE TIME This menu show the total UNIT LIFE TIME (reset not possible) and the RGB life TIME (reset possible) ENTER Up-Down Measure Life Total Unit Life Time Reset not possible ENTER Delta R Total LIFE Days Hours Min Sec 1 19 47 55 UP/DW Change Measure Measure Life Delta R RED LIFE To resed Red life time,keep pushed Enter button for more than 5 seconds ENTER Days Hours Min Sec 0
Up-Down Dmx ENTER Up-Down DMX This menu show the DMX channel levels Up-Down Voltage Measure VOLTAGE ENTER Temperature V V V V Motor Power Internal Oled TWILIGHT This menu show the twilight level. ENTER ENTER 36,9 160,5 17,6 13,2 Up-Down ENTER Measure TEMPERATURE Celsius Twilight All the values are espressed in Volt LED’s temperature monitor ENTER TEMPERATURE This menu show the NTC sensor temperature.
DELTA R 9- OPENING UP THE PROJECTOR HOUSING: It is possible to inspect the inside of the projector by removing the covers as shown below. Attention: REMOVE MAINS POWER PRIOR TO ACCESSING THE PROJECTOR'S INTERNAL COMPONENTS. Proceed as per the pictures below 9.1- Arms Remove these two screws on both arm sides 9.
DELTA R 26 10- CHANGHING THE LENSES Delta R Full Color Optical Lenses set can be interchanged by users. Three different models are available: (spot / medium /wide) Lenses set spot (cod. 03.LK.008) Lenses set medium (cod. 03.LK.001) Lenses set wide (cod. 03.LK.
DELTA R 27 10- CHANGHING THE LENSES Delta R Triled Optical Lenses set can be interchanged by users. Three different models are available: (spot / medium /wide) Lenses set spot (cod. 03.LK.008) Lenses set medium (cod. 03.LK.001) Lenses set wide (cod. 03.LK.
DELTA R 11- PERIODIC CLEANING: Front lenses Glass The dust can reduce the luminous output substantially. Regularly clean the front lenses glass using a soft cotton cloth, dampened with a specialist glasses cleaning solution. 12- PERIODIC CONTROLS: Mechanical parts: Periodically check all mechanical parts and the gaskets, replacing them if necessary. Electrical components: Check all electrical components for correct earthing and proper attachment of all connectors, refastening if necessary.
DELTA R 29 13- DMX PROTOCOL 15 CHANNELS MODE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 PAN msb 320° PAN lsb TILT msb 180° TILT lsb SPEED MOVEMENT SHUTTER DIMMER RED GREEN BLUE WHITE (Preprogrammed white at different color temperature) CTC COLOURS MACRO FUNCTIONS RESET DMX CHANNEL 1 Parameter: PAN msb DMX CHANNEL 2 Parameter: PAN lsb DMX CHANNEL 3 Parameter: TILT msb DMX CHANNEL 4 Parameter: TILT lsb DMX CHANNEL 5 Parameter: MOVEMENT SPEED DMX range Value Mid point DMX value 0-10 11-255 5 DM
DELTA R 30 DMX CHANNEL 7 DMX range Value Mid point DMX value Parameter: DIMMER Move range (degrees) NOTE: IN CMYK MODE Ch7 = BLACK Mode Option 0-255 DMX CHANNEL DMX range Value Proportional dimmer 8 Parameter: RED Mid point DMX value NOTE: IN CMYK MODE Ch8 = CYAN IN HSV MODE Ch8 = HUE Move range (degrees) Mode Option 0-255 DMX CHANNEL DMX range Value DMX range Value 9 Parameter: GREEN Mid point DMX value Move range (degrees) NOTE: IN CMYK MODE Ch9 = MAGENTA IN HSV MODE Ch9 = SATUR
DELTA R 31 DMX CHANNEL DMX range Value 12 Parameter: CTC (Color temperature correction) Mid point DMX value Move range (degrees) Mode Option Function IF CHANNEL 11 (White) = WHITE CTC (Dmx range value 214 - 255) Linear color temp.
The information contained in this publication has been carefully prepared and checked. However, no responsibility will be taken for any errors. All rights are reserved and this document cannot be copied, photocopied or reproduced, in part or completely, without prior written consent from D.T.S. D.T.S. reserves the right to make any aesthetic, functional or design modifications to any of its products without prior notice. D.T.S.