DTS Broadcast PDH Microwave Digital Radio User Manual
-83-
8.1.1 Connections of NMS
The IDU have two interfaces for NMS connection: Ethernet and RS232.
The RS232 is used for software update, here is reserved.
The Ethernet is used for SNMP/NMS.
The protocols are:
¾ Ethernet: TCP/IP, SNMP, HTTP
¾ RS232: TTY, SLIP(reserved)
The SNMP protocol is in the IDU connects PC by Ethernet with RJ-45 port in IDU.
8.1.2 Configuration for NMS’s IP
The configurations for NMS IP in IDU are:
IP address of IDU
Subnet Mask of IDU
Netgate of IDU
Agent IP address: The IP address is used for SNMP TRAP message. This message is generated by
IDU and send to NMS PC. So the IP address is address of NMS PC.
MAC address: The MAC address is located on the IDU. It is set at the factory and can be
changed.
Broadcase address: The MAC address is located on the IDU. It is set at the factory and can be
changed.
If the addresses listed above needs to be verified or changed, please use the LCD panel on the
IDU as described in Section 5.