Confidential - Do NOT Duplicate  25  DTS Document No.: 9301F55800D 
17781 v1 
Figure 7-6 Input Files Section (Stereo and Mono Case) 
Bw and Fs – Bit width Resolution and Sampling Frequency of Audio Channels 
All audio files entered for any channel layout must have the same bit-width resolution (Bw) and sampling 
frequency (Fs). 
  Note: If the sample rate of the input material does not match the selected sample rate in the 
Sample Rates drop-down menu, when the ‘Encode” button is selected, an error message will be 
displayed indicating that there is a mismatch. Unless the error is corrected, the user will not be 
able to create an encoded file.  
Clear All 
Located below the Input Files section of the GUI, the 
 button will unload all active input 
files from their related channel inputs when clicked. 
7.2.9  Dialog Normalization  
Located in the upper right side of the Audio panel, the Dialog Normalization menu allows a value to be 
selected for the specified encode (as shown in Figure 7-7). These values range from -1 to -31 dBFS 
LeqA. The default value is -31 dBFS LeqA, which corresponds to no attenuation, in effect turning dialog 
normalization OFF. At current, all 6.x Discrete channel layouts require a -31 dBFS Dialog Normalization 
setting. Dialog Normalization is a post-process operation performed by the DTS decoder. DTS 
recommends leaving the Dialog Normalization setting at -31. 
Figure 7-7 Dialog Normalization 