To secure the EMA mounting system to a wall made of dry wall, sheet rock, gypsum, or
p
laster, it is required to first mount a ¾ inch thick (19 mm) minimum plywood base
onto the wall, to provide solid support for the EMA mounting plate. The plywood base
shall be securely attached to the structural members (wood or steel supports) of the
wall. Then attach the EMA mounting plate to the plywood base.
Figure 6. Mark mounting plate location and screw hole locations.
d. Drill pilot holes at the markings for the fasteners. The drill bit must be smaller than the
diameter of the fastener used.
Figure 7. Drill pilot holes for mounting plate fasterners.
e. With four (4) proper fasteners, secure mounting plate to wall. (See figure 8.)
Fastener size should be larger than ¼ inch (6 mm) to maximum 5/16 inch (8 mm). Since the
type of fastener depends on the material used in the wall, DTS does not provide these
fasteners.
Caution: Over-tightening the fasteners can weaken the mounting surface,
damage the fasteners, and make the attachment less secure.