User`s manual
7- MOUNTING THE LAMPS
Warning: Switch off the unit before replacing the lamp.
1) Using a screwdriver, loose the 3 screws A, B, C, (photo 1) and remove the metal cover .
2) Insert the lamp (photo2).
3) Rotate the lamp 1/4 turn clockwise (photo 3 and 4).
The lamp used on XR300 BEAM is made in quartz glass and should be handled with care. Always follow
the instructions supplied in the lamp's packaging. Never touch the glass directly but use the tissue
provided in the lamp's packaging. The lamp socket is symmetrical.
DO NOT USE UNDUE FORCE ON THE GLASS. In case of difficulty, read again the instructions and repeat
the procedure.
4) Replace the metal cover and tighten the screws A,B,C, which were previously removed.
WARNING: Never look directly at the lamp when it’s lit.
Discharge lamps emits UV rays; radiation from this lamp can cause damage to eyes and skin.
7.1 Lamp alignment
Attention: we recommend to align the lamp in the optical system to avoid overheating of the dichroic
filters and other components inside the unit. The lamp alignment is also essential to obtain the
maximum uniformity and luminous performance by the projection.
3 adjusters X, Y and
Z (photo 5)
you will have an evenly projected light beam, with no shadows or
zones wich are brighter than others.
Philips MSD Gold 300/2 Mini FastFit
Power 300W
Luminous flux 22,000 lm
Colour temperature 8.400°K
Lampbase PGJX28
Rated life 2000 hours
GJX28
1) Mount the fixture in an orientation so that it may be squarely projected onto a smooth white surface
no less than 3 meters away. 2) Using a console or the menu system, focus an open (white) beam onto
the surface and observe the beam. 3) Using a phillips-head screw driver, rotate the
until you achieve a uniform flat field.
When the lamp is correctly optimized,
ARC 1200
Photo 2Photo 1 Photo 4Photo 3
Photo 5
9
Lamp
Alignment
UV
XR300 BEAM
Osram Lok-it 300W
Power 300W
Luminous flux 24,000 lm
Colour temperature 8.000°K
Lampbase PGJX28
Rated life 2000 hours