User Guide

Cable
No.
Part Number
Length
Connections
Generator
Base
Thruster
HMI
1 200-1556-XXM
XX J5
-
OPERATIONAL
CONTROL
-
2 200-1613-XXM
XX
J11
- ENCODER
-
3
200-479-XXM
XX
J1
-
ULTRASOUND
-
4 200-1545-XXM
XX J6
J35
-
-
5 200-1553-XXM
XX J9
-
-
ETHERNET
6
One of the following:
200-1541 (240 VAC, 10A, US)
200-1542 (240 VAC, 10A, Europe)
200-1624 (240 VAC, 10A, India)
200-1576 (120 VAC)
2.4
- -
-
AC INPUT
7
One of the following:
200-1110 (240 VAC, 15A, US)
200-1111 (240 VAC, 16A, Europe)
200-1612 (240 VAC, 15A, India)
200-1541 (240 VAC, 10A, US)
200-1542 (240 VAC, 10A, Europe)
200-1624 (240 VAC, 10A, India)
(for 120 VAC models, power cord is integral to generator)
2.4
AC INPUT
-
- -
8
200-1557
5
- -
PE
-
9 200-1557
5
-
GRND
-
-
10 200-1557
5
PE
-
-
-
11
200-1380-XXM
XX J2
-
- -
12 200-1381-XXM
XX
J3
-
- -
Continued from previous page
Continued
Pneumatic Press/Thruster
Table 3-V iQ Generator and Pneumatic Press/Thruster Cables
Page 32
iQ Series Ultrasonic Generator/Power Supply ES User’s Manual
Dukane Manual Part No. 403-575-00