Specifications

Installation and Operation of 613 & E Series Gas Fired Convection Oven
20
Remove the Combustion Compartment Cover by
removing the screws located in the bottom of the
door opening.
Find the pressure tap located at the lower right
hand corner of the unit on the Right hand side of
a plumbing "Tee". The pressure tap is a 1/8" pipe
plug with a hex head.
Remove the pressure tap plug and replace with
the tting for a gas pressure meter, slack tube or
manometer.
Attach your meter.
The pressure regulator is an integral part of the dual
solenoid gas valve. Locate the adjustment screw
on the left hand side. (It has a slotted aluminum
cover cap.)
Remove the cover cap.
Open the Gas Shut Off Valve.
Turn the Main power switch to the COOK position.
With the burner on, check your meter. The manifold
pressure should be 3.5" W.C. for natural gas and
10" W.C. for propane.
Check the rating plate to verify gas types and
pressures.
  






some 


• Rotate screw inside, Clockwise to increase
pressure, Counter-clockwise to decrease pressure.
• When the proper pressure is attained, turn the
power switch to the OFF position and close Manual
Shut Off Valve.
• Remove your meter and Fitting. Replace pressure
tap plug. (You may need to add some pipe dope
to the plug to prevent a leak.)
• Turn the power switch to the ON position and open
the Manual Shut Off Valve.
• With a solution of soapy water, check for gas leaks.
Repair any leaks.
• Replace cover cap on gas valve.
• Replace Combustion Cover.
• Replace Control Panel.
Gas
Valve
Gas
Valve
Gas
Solenoid
Gas
Solenoid
Pilot
Connection
Gas
Pressure
Meter
Gas
Shutoff
Valve
Gas
Shutoff
Valve
3
2
1
0
4
5
6

It is important that the ventilation system be inspected
and/or maintained by Qualied Personnel at least once
each year.
This inspection/maintenance should consist of, but
not be limited to:
• Inspection for blockages or build up which might
interfere with the venting of the oven.
• Repair of such blockages.
• Proper installation of the drafthood or ue guard.
• Inspection of the venting canopy, its drive motors
and belts, etc.
Proper preventive maintenance can reduce your
chances of costly repairs.