Installation and Operation of 613 & E Series Gas Fired Convection Oven


These installation instructions are for the use of qualied
installation and service personnel only. Installation or
service by other than qualied personnel may result in
damage to the oven and/or injury to the operator.
Qualied installation personnel are those individuals,
rms, companies or corporations which either in person or
through an agent is engaged in and responsible for:
• The installation or replacement of gas piping or
the connection, installation, repair or servicing of
equipment, who are experienced in such work,
familiar with all precautions required, and have
complied with all requirements of state and local
authorities having jurisdiction. See: National Fuel
Gas Code NFPA 54 (ANSI Z223.1).
• The installation of electrical wiring from the electric
meter, main control box or service outlet to the
electrical appliance. Qualied installation personnel
must be familiar with all precautions required and
have complied with all requirements of state and
local authorities having jurisdiction. See: National
Electrical Code, ANSI/NFPA70.
The installation must conform with local codes, or in the
absence of local codes, with the National Fuel Gas Code,
ANSI Z223.1/NFPA 54, or the Natural Gas and Propane
Installation Code, CSA B149.1 as applicable, including:
• The appliance and its individual shutoff valve must
be disconnected from the gas supply piping system
during any pressure testing of that system at test
pressures in excess of 1/2 psi (3.5 kPa).
• The appliance must be isolated from the gas supply
piping system by closing its individual manual
shutoff valve during any pressure testing of the
gas supply piping system at test pressures equal
to or less than 1/2 psi (3.5 kPa).
For an oven equipped with casters, the installation
shall be made with a connector that complies with the
Standard for Connectors for Movable Gas Appliances,
ANSI Z21.69/CSA 6.16 and a quick-disconnect device
that complies with the Standard for Quick-Disconnect
Devices for Use with Gas Fuel, ANSI Z21.4/CSA
6.9. When installing the oven with casters and quick-
disconnect hose, adequate means must be provided to
limit the movement of the oven without depending on
the connector and the quick disconnect device or its
associated piping to limit the oven movement. Restraining
means may be attached to the vertical portion of the
base frame in the rear of the oven.

Duke Manufacturing Co. does everything within its
power to insure you received your oven in good
condition. They are strapped down on heavy wooden
skids and surrounded by heavy “tri-wall” cartons to
prevent shipping damage. They have all been carefully
inspected before they were packaged and consigned
to the carrier.
Upon delivery of your Duke oven:
• Look over the shipping container, carefully noting
any exterior damage on the delivery receipt,
which must also be signed by the driver/ delivery
person.
• Uncrate and check for any damage, which was not
evident on the outside of the shipping container.
This is called concealed damage. The carrier must
be notied within fteen (15) days of the delivery
of the oven and the carton, skid and all packaging
materials must be retained for inspection.
Duke Manufacturing Co. cannot assume liability for
loss or damage suffered in transit. The carrier assumes
full responsibility for delivery in good order when the
shipment was accepted. However, we are prepared to
assist you in ling your claim.

Proper planning and placement of the oven will give you
the best results in terms of long-term user convenience
and satisfactory performance. We urge you to give
adequate thought in the placement of your oven prior
to its arrival.
• The oven should be placed in an area that is free
from drafts and accessible for proper operation
and servicing.
• The area around the oven must be kept clear
of combustible materials. A minimum clearance
must be maintained between the oven and any
combustible or non-combustible surface.

Combustible Non-Combustible
RIGHT SIDE 1" 0"
LEFT SIDE 1" 0"
REAR 3" 3"
FLOOR 8" 8"