Installation Guide
www.factorybuysdirect.com
200257-01A22
INSPECTING BURNERS
IMPORTANT: Owner’s should check pilot ame pattern and burner ame pattern often.
Incorrect ame patterns indicate the need for cleaning (see Care and Maintenance,
page 23 or service.
WARNING: Only a qualied service person should service and
repair stove. This includes maintenance requiring replacement or
alteration of components.
PILOT FLAME PATTERN
Figure 26 - Correct Pilot Flame Pattern
(Natural Gas shown)
Figure 27 - Incorrect Pilot Flame Pattern
(Natural Gas shown)
Figure 26 shows a correct pilot ame pattern.
Figure 27 shows an incorrect pilot ame pat-
tern. The incorrect pilot ame is not touching
the thermocouple. This will cause the ther-
mocouple to cool, which shuts the stove off.
If pilot ame pattern is incorrect, as shown
in Figure 27
• turn stove off (see To Turn Off Gas to Ap-
pliance, page 19)
• see Troubleshooting pages 26 through 29.
WARNING: If yellow tipping
occurs, the pilot should be
cleaned.
Notice: Do not mistake orange ames with
yellow tipping. Dirt or other ne particles enter
the stove and burn causing brief patches of
orange ame.
Approx. 3"-6" Above Top of Logs
More Than 8" Above Top of Logs
Approx. 3"-6" Above Top of Logs
More Than 8" Above Top of Logs
Figure 28 - Correct Burner Flame Pattern
Figure 29 - Incorrect Burner Flame
Pattern
BURNER FLAME PATTERN
Figure 28 shows a correct burner ame pattern. Figure 29 shows an incorrect burner ame
pattern. If burner ame pattern is incorrect as shown in Figure 29:
• turn stove off (see To Turn Off Gas to Appliance, page 19).
• see Troubleshooting pages 26 through 29.
BURNER PRIMARY AIR HOLES
Air is drawn into the burner through the holes in the tting at the entrance to the burner. These
holes may become blocked with dust or lint. Periodically inspect these holes for any blockage
and clean as necessary. Blocked air holes will create soot.
NG
3-3.5" WC
Natural Gas
Shown
LP
8-11" WC
NG
3-3.5" WC
Natural Gas
Shown
LP
8-11" WC