Installation Guide
www.factorybuysdirect.com
19HSE-MAN-013
OPERATION
THERMOSTAT CONTROL OPERATION
The thermostatic control used on this model diers from standard thermostats. Standard ther-
mostats simply turn the burner on and o. The thermostat used on this heater senses the room
temperature. At times the room may exceed the set temperature. If so, the burner will shut o.
The burner will cycle back on when room temperature drops below the set temperature. The
control knob can be set to any comfort level between Low (1) and HIGH (5).
Shutting Off Heater
Turn control knob clockwise to the
OFF position.
Shutting Off Burner Only (pilot
stays lit )
Turn control knob clockwise to the
PILOT position.
1. Follow steps 1 through 5 under Lighting
Instructions, page 18.
2. With control knob in PILOT position, strike
match, and hold near pilot. Press in control
knob; pilot should light.
3. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
4. Make sure the heater screen is in place
before operating heater.
TO TURN OFF GAS TO APPLIANCE
MANUAL LIGHTING PROCEDURE