Installation Guide

www.factorybuysdirect.com
HSE-MAN-01326
TROUBLESHOOTING
Problem Possible Cause Corrective Action
Heater produces un-
wanted odors.
1. Heater is burning vapors from
paint, hair spray, glues, etc.
See IMPORTANT statement,
page 25.
2. Gas leak. See Warning State-
ment at the top of page 22.
3 Low fuel supply.
1. Ventilate room. Stop using
odor causing products while
heater is running.
2. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 14).
3. Rell supply tank (Propane/
LP models).
Heater shuts o in use
(ODS operates).
1. Not enough fresh air is avail-
able.
2. Low line pressure.
3. ODS/pilot is partially
clogged.
1. Open window and/or door for
ventilation.
2. Contact local gas supplier.
3. Clean ODS/pilot (see Care
and Maintenance, page 21).
Gas odor exists even
when control knob is in
OFF position.
1. Gas leak. See Warning
Statement at top of page 22.
2. Control valve is defective.
1. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 14).
2. Replace control valve.
Moisture/condensation
noticed on windows.
1. Not enough combustion/
ventilation air.
1. Refer to Air for Combus-
tion and Ventilation require-
ments, page 7.