Use and Care Manual

10
www.factorybuysdirect.com
200273-01C
Figure 4 - Minimum Clearance for
Combustible to Wall
INSTALLATION
CLEARANCES TO
COMBUSTIBLES
WARNING: Maintain the
minimum clearances. If possible,
provide greater clearances from
oor, ceiling, and adjoining wall.
Measure from outermost point
of heater.
Minimum Fireplace Clearance To
Combustible Materials
Side Wall 16", Ceiling 42", Front 36"
LOG SIZING REQUIREMENTS
Minimum Firebox Size
24" Log Set: Height 20", Depth 15",
Front Width 28", Rear Width 23"
30" Log Set: Height 20", Depth 15",
Front Width 34", Rear Width 23"
Minimum Clearances For Side
Combustible Material, Side Wall
and Ceiling
A. Clearance from the side of the replace
cabinet to any combustible material and
wall should follow diagram in Figure 4.
B. Clearance from the top of the replace
opening to the ceiling must not be less
than 42".
Minimum Noncombustible Material
Clearances
If Not Using Mantel
Note: If using a mantel, proceed to If Using
Mantel. If not using a mantel, follow the infor-
mation below.
You must have noncombustible material(s)
above the replace opening. Noncombustible
materials (such as slate, marble, tile, etc.)
must be at least 1/2" thick. With sheet metal,
you must have noncombustible material be-
hind it. Noncombustible material must extend
at least 12" up (for all models). See Figure 5
for minimum clearances.
*Minimum 16" from Side Wall
*
Figure 5 - Heat Resistant Material (Slate,
Marble, Tile, etc.) Above Fireplace
Noncombustible
Material Distance
Requirements for Safe Installation
(A) 12" or more: Noncombustible
material OK.
(A) Between 8" and 12":
Install replace hood accessory.
(A) Less than 8": Noncombustible
material must be extended to at least 8".
See Between 8" and 12", above. If you
cannot extend material, you must operate
heater with ue damper open.