Use and Care Manual

5
www.factorybuysdirect.com
200273-01C
SPECIFICATIONS
PRODUCT FEATURES
This log set has been tested and approved to
ANSI Z21.11.2 standard for Unvented Heat-
ers and can be operated with the ue damper
closed. State and local codes in some areas
prohibit the use of vent-free heaters.
SAFETY PILOT
This heater has a pilot with an Oxygen Deple-
tion Sensing (ODS) safety shuto󰀨 system. The
ODS/pilot shuts o󰀨 the heater if there is not
enough fresh air.
PIEZO IGNITION SYSTEM
This heater is equipped with an electronic
piezo control system. This system requires a
AAA battery (provided).
THERMOSTAT HEAT CONTROL
When the hand held remote is in the THERMO
mode, it automatically cycles the burner
on and off to maintain a desired room
temperature.
2 GAS OPTIONS AVAILABLE
Your heater is equipped to operate on either
propane or natural gas. The heater is shipped
from the factory ready for connecting to pro-
pane. The heater can easily be changed to
Natural gas by having your qualied installer
follow the instructions on page 13 and the
markings on the heater.
Figure 1 - Vent-Free Log Chassis
Ignitor Button
Control Knob
Burner
Pilot
PRODUCT IDENTIFICATION
*For purposes of input adjustment
Models FDLR24/30-1
Gas Type Natural Gas Propane Gas
Ignition Electronic Piezo Ignitor Electronic Piezo Ignitor
Input Rating
33,000 Btu/Hr 33,000 Btu/Hr
Manifold Pressure 4" W.C. 9" W.C.
Inlet Gas Pressure* (inches
of water) (*for purposes of
input adjustment)
Maximum 9.5" Maximum 14"
Minimum 5" Minimum 11"