PRODUCT FEATURES
ON/OFF SAFETY PILOT VALVE KIT WITH PROPANE/LP CONVERSION
An optional on/off valve/safety pilot kit with a piezo ignitor is available for this appliance. This 
system requires no matches, batteries, or other sources to light. You must use this optional 
system for Propane/LP conversion.
Install  and  use  heater  with  care.  Follow  all 
local codes.  In  the absence  of local  codes, 
use  the  latest  edition  of  The National Fuel 
Gas Code, ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
1 Batterymarch Park
Quincy, MA 02269-9101
LOCAL CODES
State of Massachusetts: The installation 
must  be  made  by  a  licensed  plumber  or 
gas  tter  in  the  Commonwealth  of  Mas-
sachusetts.
Sellers  of  unvented  propane  or  natural 
gas-red supplemental room heaters shall 
provide  to  each  purchaser  a  copy of  527 
CMR 30 upon sale of the unit.
In  the  State  of  Massachusetts  the  gas 
cock must  be  a T-handle type. The  State 
of  Massachusetts  requires  that  a  exible 
appliance connector cannot exceed three 
feet in length.
Minimum Free Opening Area of Chimney Damper 
for Venting (sq. in.) For Factory-Built Fireplaces
Chimney Height 14" 18" 24"
15' (Min) 41 47 53
20' 37 43 48
30' 33 38 43
FUEL INLET PRESSURE SPECIFICATIONS (W.C.)
Natural Gas Minimum 5.5" W.C. Maximum 10.5" W.C.
Propane/LP Gas* Minimum 11" W.C. Maximum 11" W.C.
* For use if unit is converted to Propane/LP gas.
SPECIFICATIONS
Model FGB14-1 FGB18-1 FGB24-1
Gas Type Natural Natural Natural
BTU Input* 45,000 BTU/Hr 55,000 BTU/Hr 65,000 BTU/Hr
Minimum Vent Opening 8" Diameter 8" Diameter 8" Diameter
Burner Orice (Propane/LP)** 205 (mm) 225 (mm) 242 (mm)
* Btu/Hr Rating is the same when unit is converted to Propane/LP gas.
** Number is printed on orice. Located in NVDWA2 kit when converting to LP gas.