INSTALLATION
TESTING BURNER FOR LEAKS
 WARNING: Never check for 
gas leaks with open ame.
1.  Generously  apply  a  noncorrosive  leak 
detection uid to all connections.
2.  Light the burner with the shutoff valve, no 
more than half open, and holding a match 
slightly in  front  of the  pan  (see Lighting 
Instructions, page 12).
3.  Inspect  all  connections  for  bubbles, 
raw  gas  odor,  or  ame  from  any  area 
other than the burner (leaks). If leaks are 
detected, shut off the gas valve immedi-
ately.  Tighten,  or  reassemble  the  loose 
connection(s) using pipe joint compound 
until burner system is leak free.
4.  When the burner is tested and leak free, 
observe the  individual  tongues of ame 
on the burner.
  Note:  Let  the  burner  manifold  cool  rst 
before removing to unclog port blockages. 
The burner design includes more ports 
on the outside of the bar. Make sure that 
all  ports  are  clear  and  producing  ame 
evenly across the burner. If any ports 
appear blocked, clear them by removing 
the burner manifold and reaming the ports 
with  a  modied  paper  clip  or  other  suit 
able tool.
5.  When nished testing, turn the gas shutoff 
valve OFF to extinguish all ames.