Installation Guide
www.factorybuysdirect.com
9200254-01A
INSTALLATION
CONNECTION TO GAS SUPPLY
  WARNING: A  qualied  ser-
vice  person  must  connect  ap-
pliance to gas supply. Follow all 
local codes.
Installation Items Needed
Before  installing  appliance,  make  sure  you 
have the items listed below.
•  piping (check local codes)
•  sealant (resistant to natural gas)
•  equipment shutoff valve
•  test gauge connection
•  adjustable (crescent) wrench or pliers
•  sediment trap
•  tee joint
•  pipe wrench
 CAUTION: Only use a new, 
black  iron  or  steel  pipe.  Inter-
nally-tinned copper tubing may 
be used in certain areas. Check 
your  local  codes.  Use  pipe  of 
1/2" diameter or greater to allow 
proper gas volume to appliance. 
If pipe is too small, loss of pres-
sure will occur.
Installation must include an equipment shut-
off valve, union, and plugged 1/8" NPT tap. 
Locate NPT tap within reach  for test gauge 
hook  up.  NPT  tap  must  be  upstream  from 
appliance (see Figure 8).
IMPORTANT: Install equipment shutoff valve 
in  an  accessible  location.  The  equipment 
shutoff valve is for turning on or shutting off 
the gas to the appliance.
Apply pipe joint sealant lightly to male threads. 
This will prevent excess sealant from going 
into pipe. Excess sealant in pipe could result 
in a clogged burner injector.
Install sediment trap in supply line as shown 
in Figure 8. Locate sediment trap where it is 
within  reach  for  cleaning.  Locate  sediment 
trap  where  trapped  matter  is  not  likely  to 
freeze. A  sediment  trap  traps  moisture  and 
contaminants.  This  keeps  them from  going 
into appliance controls. If sediment trap is not 
installed or is installed incorrectly, appliance 
may not run properly.
Figure 8 - Gas Connection
Approved Flexible Gas Hose 
(if allowed by local codes)
CSA Design - Certied 
Equipment Shutoff Valve 
with 1/8" NPT Tap*
3" Minimum
From Gas Meter 
(5" W. C.**
to 10.5" W. C.) 
pressure
Sediment Trap
Cap  Pipe  Tee
  Nipple  Joint
* Purchase the optional CSA design-certied 
equipment  shutoff  valve  from  dealer.  See 
Accessories page 19.
** Minimum inlet pressure for purpose of input 
adjustment.