Installation Guide

www.factorybuysdirect.com
11200254-01A
INSTALLATION
TESTING BURNER FOR LEAKS
WARNING: Never check for
gas leaks with open ame.
1. Generously apply a noncorrosive leak
detection uid to all connections.
2. Light the burner with the shutoff valve, no
more than half open, and holding a match
slightly in front of the pan (see Lighting
Instructions, page 12).
3. Inspect all connections for bubbles,
raw gas odor, or ame from any area
other than the burner (leaks). If leaks are
detected, shut off the gas valve immedi-
ately. Tighten, or reassemble the loose
connection(s) using pipe joint compound
until burner system is leak free.
4. When the burner is tested and leak free,
observe the individual tongues of ame
on the burner.
Note: Let the burner manifold cool rst
before removing to unclog port blockages.
The burner design includes more ports
on the outside of the bar. Make sure that
all ports are clear and producing ame
evenly across the burner. If any ports
appear blocked, clear them by removing
the burner manifold and reaming the ports
with a modied paper clip or other suit
able tool.
5. When nished testing, turn the gas shutoff
valve OFF to extinguish all ames.