INSTALLATION
CONNECTING TO GAS SUPPLY
 WARNING: A qualied service 
technician must connect appliance 
to gas supply. Follow all local codes.
  WARNING: This appliance 
requires  a  3/8"  NPT  (Nation-
al Pipe Thread) inlet connec-
tion to the pressure regulator. 
 WARNING: For natural gas, 
Never connect appliance to private 
(non-utility) gas wells. This gas is 
commonly known as wellhead gas. 
 CAUTION: For propane gas, 
never connect appliance directly 
to the gas supply. This appliance 
requires an external regulator (not 
supplied). Install the external regu-
lator  between  the  appliance  and 
propane supply. Gas supplier pro-
vides external regulator for natural 
gas. The installer provides the 
external regulator for propane gas.
 CAUTION: For propane gas, 
never connect appliance directly 
to the gas supply. This appliance 
requires an external regulator (not 
supplied). Install the external regu-
lator  between  the  appliance  and 
propane supply. Gas supplier pro-
vides external regulator for natural 
gas. The installer provides the 
external regulator for propane gas.  
 CAUTION: Use only new, 
black iron or steel pipe. Internally 
tinned copper tubing may be used 
in certain areas. Check your local 
codes. Use pipe of 1/2" diameter or 
greater to allow proper gas volume 
to  replace.  If  pipe  is  too  small, 
undue loss of pressure will occur
 CAUTION: For natural gas, 
check your gas line pressure be-
fore connecting appliance to gas 
line. Gas line pressure must be no 
greater than 10.5" WC for natural 
gas and 13" WC for propane. If gas 
line pressure is higher, appliance 
regulator damage could occur.
 WARNING: Do not over-tighten 
gas connections.
 CAUTION: use pipe joint 
sealant that is resistant to gas 
(Propane or Natural Gas). 
For appliances for use with a xed 
fuel piping system and equipped 
with an appliance gas pressure 
regulator, the appliance and its 
individual shutoff valve must 
be disconnected from  the gas 
supply piping system during any 
pressure testing of that system 
at test pressures in excess of 1/2 
psi (3.5 kPA). 
The  appliance  must  be  isolated 
from the gas supply piping system 
by  closing  its  individual  manual 
shuto valve during any pressure 
testing of the gas supply piping 
system at test pressures equal to 
or less than 1/2 psi (3.5 kPa).
     
•      
•  
•      
•  
•  
•  
•  
•  
•  
-