Installation Guide
www.factorybuysdirect.com
17200337-01A
Figure 17 - Equipment Shutoff Valve
CHECKING GAS CONNECTIONS
Open
Closed
Equipment 
Shutoff Valve
1.  Disconnect heater with its appliance main 
gas valve (control valve) and equipment 
shutoff valve from gas supply piping sys-
tem. Pressures in excess of 1/2 PSIG will 
damage heater regulator.
2.  Cap off open end of gas pipe where equip-
ment shutoff valve was connected.
3.  Pressurize supply piping system by either 
using compressed air or opening gas sup-
ply valve.
INSTALLATION
 WARNING: Test all gas piping 
and connections for leaks after 
installing  or  servicing.  Correct 
all leaks at once.
 WARNING: Never use an open 
ame to check for a leak. Apply a 
mixture of liquid soap and water 
to all joints. If bubbles form, there 
is a leak. Correct all leaks at once.
PRESSURE TESTING GAS SUPPLY PIPING SYSTEM
Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)
4.  Check  all  joints  of  gas  supply  piping 
system. Apply mixture of liquid soap and 
water to gas joints. If bubbles form, there 
may be a leak.
5.  Correct all leaks at once.
6.  Reconnect heater and equipment shutoff 
valve to gas supply. Check reconnected 
ttings for leaks.
Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)
1. 
Close equipment shutoff valve (see Figure 17).
2.  Pressurize supply piping system by either 
using compressed air or opening gas sup-
ply valve.
3.  Check all joints from gas supply (see Fig-
ure 18 or 19) to equipment shutoff valve. 
Apply a noncorrosive leak detection uid 
to all joints. Bubbles forming show a leak.
4.  Correct all leaks at once.
PRESSURE TESTING HEATER GAS CONNECTIONS
to all joints. Bubbles forming show a leak.
5.  Correct all leaks at once.
6.  Light heater (see Lighting Instructions on 
page 18). Check all  other internal joints 
for leaks.
7.  Turn off heater (see To Turn Off Gas Ap-
pliance, page 19).
1. 
Open equipment shutoff valve (see Figure 17).
2.  Open gas supply tank valve.
3.  Make sure control knob of heater is in the 
OFF position.
4.  Check  all  joints  from  equipment  shutoff 
valve to control valve (see Figure 18 or 19). 
Apply a noncorrosive leak detection uid 
Gas Valve
Gas Valve
Equipment 
Shutoff Valve
Equipment Shutoff Valve
Propane/LP 
Supply Tank
Figure 18 - Checking Gas Joints for 
Propane/LP Gas
Figure 19 - Checking Gas Joints for 
Natural Gas
Gas Meter