Shutting Off Heater
Turn control knob clockwise to the
OFF position.
Shutting Off Burner Only
(pilot stays lit)
Turn control knob clockwise to the
PILOT position.
1. Follow steps 1 through 7 under Lighting
Instructions, above.
2. With control knob in PILOT position,
strike match, and hold near pilot. Press
in control knob; pilot should light.
3. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
TO TURN OFF GAS TO APPLIANCE
MANUAL LIGHTING PROCEDURE
THERMOSTATIC CONTROL OPERATION
Model FLT24-1-LP and FLT24-1-NG Log Sets Only
The thermostatic control used on this model
differs from standard thermostats. You set
standard thermostats to a specic tempera-
ture (such as 72 degrees); the control of this
heater establishes a “comfort level”. In order
for the thermostat to operate effectively, the
heater should be the main source of heat in
the ROOM. Follow the instructions for light-
ing the heater, and turn the knob to the HIGH
position. When the room reaches the desired
comfort level, rotate the control knob clock-
wise slowly to the point where the main burner
extinguishes (this point on the dial will change
depending on room temperature), then back
counter-clockwise -just until the ame reig-
nites. Leave the knob in this position. As the
room temperature increases, the burner will
automatically return to "Pilot Only" operation.
When the room temperature cools, the heater
will come back on. The main burner cycles off
and on as needed to maintain the temperature
at this comfort level setting.
OPERATION
Ignitor Button
Control Knob
Figure 19 - Ignitor Button and Control
Knob Locations
Figure 20 - Pilot Assembly
Gas Burner
Thermocouple
Ignitor
Electrode
ated after connecting the gas supply, the
control knob should be pressed for about
thirty (30) seconds. This will allow air to
bleed from the gas system. If pilot does not
stay lit, refer to Troubleshooting, pages 21
though 23. Also contact a qualied service
technician or gas supplier for repairs. Until
repairs are made, light pilot with match.
If control knob does not pop up when
released, contact a qualified service
technician or gas supplier for repairs.
6. With control knob pressed in, push
down and release ignitor button. This
will light pilot. The pilot is attached to
the rear of the burner. If needed, keep
pressing ignitor button until pilot lights.
Note: If pilot does not stay lit, refer to
Troubleshooting, pages 21 though 23.
Also contact a qualied service technician
or gas supplier for repairs. Until repairs are
made, light pilot with match. To light pilot
with match, see Manual Lighting Procedure.
7. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
Note: If pilot goes out, repeat steps 7
through 10. This heater has a safety in-
terlock system. Wait one (1) minute before
lighting pilot again.
8. Turn control knob counterclockwise
to the ON position. The main burner
should light. Set control knob to the de-
sired heating level.
Note: Please wait one minute after shut-
ting off heater to allow the control valve
to reset before starting again.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.