Instructions / Assembly
www.factorybuysdirect.com
200245-01D10
INSTALLATION
Yellow Natural Gas 
Plunger Underneath 
Metal Cap
Blue Propane 
Gas Plunger 
Underneath Dust 
Cover
Figure 5 - Gas Regulator
Insert Gas Fitting 
for Natural Gas
Insert Gas Fitting 
for Propane Gas
GAS SELECTION
This appliance is factory 
preset for propane gas. No 
changes are required for 
connecting to propane. Only a 
qualied installer or service tech-
nician can perform gas selection 
and connecting to gas supply.
  CAUTION:  Two  gas  line  in-
stallations at the same time are 
prohibited.
 CAUTION: To avoid gas leak-
age for the gas not being used at 
the inlet of regulator, a qualied 
installer  or service  technician 
must use supplied cap.
You will notice a color coded 
plunger on the inside of the regula-
tor. This is normal. When the inlet 
connection tting is  inserted 
and tightened, this plunger will 
be  pushed  back  by  the  tting 
making  all  of  the  adjustments 
for the gas being supplied. DO 
NOT  REMOVE  THE  PLUNGER. 
The regulator will not work.
The inlet regulator is color coded 
for identication of the correct 
gas type. Blue is for propane (LP 
gas) and yellow is for natural gas.
Blue Dust 
Cover
DO NOT REMOVE
Blue Propane Plunger
Install Gas Fitting Here
FOR PROPANE GAS 
INSTALLATION: BLUE
1.  Remove blue dust cover.