Technical Specifications
Product Name: FILL AND SEAL (TM) 120Z Expanding Foam
Sealant
Issue Date: 01/31/2008
Page 5 of 13
OSHA Table
Z-1
Ceiling 0.2 mg/m3 0.02 ppm
|
Methyl ether WEEL TWA 1,880 mg/m3 1,000 ppm
|
Isobutane ACGIH TWA 1,000 ppm
|
Propane
OSHA Table
Z-1
PEL 1,800 mg/m3 1,000 ppm
ACGIH TWA 1,000 ppm
|
Personal Protection
Eye/Face Protection: Use safety glasses. Eye wash fountain should be located in immediate work
area.
Skin Protection: Use protective clothing chemically resistant to this material. Selection of specific
items such as face shield, boots, apron, or full body suit will depend on the task. Remove
contaminated clothing immediately, wash skin area with soap and water, and launder clothing before
reuse or dispose of properly. Items which cannot be decontaminated, such as shoes, belts and
watchbands, should be removed and disposed of properly.
Hand protection: Use gloves chemically resistant to this material. Examples of preferred
glove barrier materials include: Butyl rubber. Chlorinated polyethylene. Polyethylene. Ethyl
vinyl alcohol laminate ("EVAL"). Examples of acceptable glove barrier materials include:
Natural rubber ("latex"). Neoprene. Nitrile/butadiene rubber ("nitrile" or "NBR"). Viton.
Polyvinyl chloride ("PVC" or "vinyl"). NOTICE: The selection of a specific glove for a particular
application and duration of use in a workplace should also take into account all relevant
workplace factors such as, but not limited to: Other chemicals which may be handled, physical
requirements (cut/puncture protection, dexterity, thermal protection), potential body reactions
to glove materials, as well as the instructions/specifications provided by the glove supplier.
Respiratory Protection: Atmospheric levels should be maintained below the exposure guideline.
When atmospheric levels may exceed the exposure guideline, use an approved air-purifying respirator
equipped with an organic vapor sorbent and a particle filter. For situations where the atmospheric
levels may exceed the level for which an air-purifying respirator is effective, use a positive-pressure
air-supplying respirator (air line or self-contained breathing apparatus). For emergency response or
for situations where the atmospheric level is unknown, use an approved positive-pressure self-
contained breathing apparatus or positive-pressure air line with auxiliary self-contained air supply. The
following should be effective types of air-purifying respirators: Organic vapor cartridge with a
particulate pre-filter.
Ingestion: Use good personal hygiene. Do not consume or store food in the work area. Wash hands
before smoking or eating.
Engineering Controls
Ventilation: Use only with adequate ventilation. Local exhaust ventilation may be necessary for some
operations. Provide general and/or local exhaust ventilation to control airborne levels below the
exposure guidelines. Exhaust systems should be designed to move the air away from the source of
vapor/aerosol generation and people working at this point. The odor and irritancy of this material are
inadequate to warn of excessive exposure.
9. Physical and Chemical Properties
Physical State
Foam
Color
Yellow
Odor
Mild
Flash Point - Closed Cup
-104 °C (-155 °F)
Estimated
Flammable Limits In Air Lower: No test data available
Upper: No test data available
Autoignition Temperature
No test data available
Vapor Pressure
1,151 kPa @ 55 °C Calculated
Boiling Point (760 mmHg)
Not applicable.
Vapor Density (air = 1)
No test data available
Specific Gravity (H2O = 1)
1.06 Estimated