Application Guide

Heat Surge Fireplace Insert Troubleshooting
NO POWER
When the fireplace insert is plugged into a 120vac, 60HZ power source, an audible BEEP shall emit from the
Main Printed Circuit Board.
If NO BEEP, check following:
Verify OUTLET/CURCUIT is on and in good operating condition.
Verify CORD & PLUG are not damaged or broken.
Check & Press 15AMP RESET SWITCH.
Tip unit back & forth and side to side to ensure TIP SWITCH pendulum is hanging straight down and free.
NOTE: If INSERT is off due to a previous BEEP SHUTDOWN, INSERT must remain unplugged and allow
the COOL DOWN to reset FUSIBLE LINK for 7 to 10 MINUTES.
If still NO BEEP, remove INSERT from Mantle and remove TOP ACCESS PANEL to reveal electronic
components for testing.
To remove INSERT on newer models from Mantle, place unit face down, remove 4 SCREWS holding insert to
TOP & BOTTOM BRACKETS on the back. Lift Mantle straight up and off. INSERT will come out through
the front. Older models have 4 SCREWS and 4 TABS holding unit to inside front of Mantle. Remove 4
SCREWS from wood, Bend 4 TABS back away from wood front towards the side of INSERT. Lift Mantle
straight up and off. INSERT will come out through the front.
Check all internal connections from CORD to MAIN PRINTED CURCUIT BOARD (MPCB). Individually
or together test continuity of CORD, 15AMP RESET SWITCH and TIP SWITCH. Test power at 15AMP
RESET SWITCH and TIP SWITCH. Replace if no power present. If no power present on MPCB, replace
MPCB.
Side note: Malfunctioning MOTOR will cause heat to shut OFF or complete SHUTDOWN of INSERT.