Install Manual

33
Appendix A: Battery Expansion Cabinet Installation batteries #5 to #8
The DURACELL POWER CENTER 5 kW system supports up to two additional expansion cabinets. Where duplicated, the
mechanical assembly and wiring instructions will be referenced to previous sections within this document. All instructions
specific to the first expansion cabinet are documented below, with battery modules numbered 5 to 8 inclusively. Startup
and operation, section 8, remains unchanged.
A.1 Initial Inspection of Material List – top level system components
The system components supplied with your DURACELL POWER CENTER 5 kW are shown below. Each component should be
inspected visually for any damage that may have been caused by shipment. If damage is present, please contact your
local distributor.
2.6.1 LFP expansion install kit – mechanical parts
Item Qty DURACELL P/N Description
1 1 D-14kWh-LFP kit Incl. cabinet coupler assembly, two levelling brackets, and two plugs
2 8 Adhesive backed battery module pads
3 1 Battery rack partition bracket (includes attached battery retaining clip)
Item DURACELL P/N Description
1 D-14kWh-LFP Battery Cabinet (and cover)
2 - Expansion wall mount bracket
3 US3000C 4 battery modules
4 LFP expansion install kit Assembly parts kit and cables
1
2
3
4
D-14kWh-LFP kit
M4 x 25 mm
1
3
4
8x