8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Control parameters
Exposure Guidelines
Chemical name ACGIH TLV OSHA PEL NIOSH IDLH
Lead
7439-92-1
TWA: 0.05 mg/m
3
TWA: 50 µg/m
3
TWA: 50 µg/m
3
Pb
Action Level: 30 µg/m
3
Poison,
See 29 CFR 1910.1025 Action
Level: 30 µg/m
3
Pb Poison, See
29 CFR 1910.1025
IDLH: 100 mg/m
3
TWA: 0.050 mg/m
3
Sulfuric acid
7664-93-9
TWA: 0.2 mg/m
3
thoracic fraction TWA: 1 mg/m
3
(vacated) TWA: 1 mg/m
3
IDLH: 15 mg/m
3
TWA: 1 mg/m
3
ACGIH TLV: American Conference of Governmental Industrial Hygienists - Threshold Limit Value OSHA PEL: Occupational Safety and Health
_____________________________________________________________________________________________
1300805 - Sealed Lead Acid Battery 12V
7. HANDLING AND STORAGE
Precautions for safe handling
Handling
In case of rupture: Handle in accordance with good industrial hygiene and safety practice.
Avoid contact with skin, eyes or clothing. Use personal protection equipment.
Conditions for safe storage, including any incompatibilities
Storage
Keep containers tightly closed in a dry, cool and well-ventilated place. Protect from
moisture. Store locked up. Keep out of the reach of children. Store away from other
materials.
Incompatible Products
Acids. Bases. Oxidizing agent.
6. ACCIDENTAL RELEASE MEASURES
Personal precautions, protective equipment and emergency procedures
Personal precautions
Attention! Corrosive material. Avoid contact with skin, eyes or clothing. Ensure adequate
ventilation. Use personal protective equipment as required. Evacuate personnel to safe
areas. Keep people away from and upwind of spill/leak.
Other Information
Refer to protective measures listed in Sections 7 and 8.
Environmental precautions
Environmental precautions
Refer to protective measures listed in Sections 7 and 8. Prevent further leakage or spillage
if safe to do so. Should not be released into the environment. Do not allow to enter into
soil/subsoil. Prevent product from entering drains.
Methods and material for containment and cleaning up
Methods for containment
Prevent further leakage or spillage if safe to do so.
Methods for cleaning up
Pick up and transfer to properly labeled containers.
Page 5 / 12