Certifications 2

Page 1 of 4
Material Safety Data Sheet
____________________________________________________________________
Section 1 - PRODUCT AND COMPANY IDENTIFICATION
Product Name: Li-ion Battery Pack
Manufacture: Duracell Licensed Factory, Shenzhen, China
Address: c/o Duracell Licensed Partner PSA Parts Ltd, 2 Prince George’s Road,
Colliers Wood, London SW19 2PX
Telephone: +44 (0)20 8685 6300
Fax: +44 (0)20 8685 6310
Email: sales@psaparts.co.uk
2. COMPOSITION / INFORMATION ON INGREDIENTS
Chemical Name
Chemical
Formula
CAS No. In % by Weight
Lithium Cobalt Dioxide LiCoO
2
12190-79-3 25~40
Graphite C 7782-42-5 11-21
Electrolyte (Lithium
Hexafluorophosphate)
LiPF
6
21324-40-3 8~18
3. HAZARDS IDENTIFICATION
Health Hazards (Acute and Chronic)
These Chemicals are contained in a sealed can. Risk of exposure occurs only if the
battery is mechanically or electrically abused. Contact of electrolyte and extruded
lithium with skin and eyes should be avoided.
Sign/Symptoms of Exposure
A shorted battery can cause thermal and chemical burns upon contact with the skin.
May be a reproductive hazard.
4. FIRST-AID MEASURES
Ingestion: Do not induce vomiting or give food or drink. Seek medical attention
immediately.
Inhalation: Provide fresh air and seek medical attention.
Eyes contact: Immediately flush eyes thoroughly with water for at least 15 minutes,
lifting upper and lower lids, until no evidence of the chemical remains. Seek medical
attention.
Skin contact: Remove contaminated clothing and thoroughly wash with soap and
plenty of water. If irritation persists, seek medical attention.
5. FIRE-FIGHTING MEASURE
Flash Point: N/A
Auto-Ignition Temperature: N/A
Extinguishing Media: Water, CO
2
Special Fire-Fighting Procedures: Self-contained breathing apparatus.