3 Product Introduction
3.1 System architecture
The POWER CENTER HUB is the communication gateway for the line of Duracell Power Center
microinverters. The gateway collects microinverter data via Wi-Fi and reports this data to the Power
Center’s server via a customer supplied internet connection, either via hard-wired ethernet (recommended)
or Wi-Fi. Local monitoring applications include PC-based web-browser and IOS / Android apps.
3.1.1 System Capacity
A single POWER CENTER HUB can monitor up to a total of 99 PV panels (PV port inputs). Mutiple gateways
can be provisioned where PV arrays exceed this limit.
3.1.2: Basic requirements & prerequisites
• 120VAC power outlet required for the POWER CENTER HUB power adapter.
• Indoor installation only. Outdoor installation requires a non-metallic, NEMA type 4 rated enclosure
(not included). Operating temperature range is -20°C to +55°C.
• Internet service required. Router with dedicated Ethernet port recommended.
• Wall-mounting bracket requires two #8 screws. Use anchors appropriate for wall material.
• Completed serial number map from the Duracell Power Center Microinverter Installation Manual.
• Installer must have a registered Installer APP account (Contact dealer/reseller for details).