Specifications

Troubleshooting Reference
975-0339-01-01 39
Green
Charging
Status light is
still flashing
and hasn’t
changed to
steady after 50
hours of
charging.
The voltage at the AC
wall outlet is less than
120 V AC.
Use AC wall outlet that supplies
120 V AC.
The engine
being jump-
started will not
start.
Duracell® Powerpack
battery is not fully
charged.
The engine condition
is poor.
External fuse (250 A)
is blown.
The engine start
capacity exceeds the
Duracell® Powerpack
jump-start capability.
Recharge the Duracell® Powerpack
battery.
Have the engine serviced.
Replace 250 A, 32 V fuse with same
type and ratings.
Upgrade to a higher power
Duracell® Powerpack.
The battery
clamps of the
jump-start
cables measure
zero volts.
External fuse (250 A)
is blown.
Replace 250 A, 32 V fuse with same
type and ratings.
The light does
not turn on.
Light bulb has burnt
out.
Remove lens cover and replace bulb
with one of the same type and rating.
The AM radio
does not work
or buzzes
continuously
The Duracell®
Powerpack AC outlets
are being used,
causing interference.
Turn off the AC outlets.
Table 5-1
Troubleshooting reference
Problem Possible Cause Solution
Duracell_600HD.book Page 39 Wednesday, June 13, 2007 4:14 PM