SDS

Article Information Sheet
According to HCS-2012 APPENDIX D TO ยง1910.1200
Version: 1.0/EN Revision date: 06/06/2020
Product name: Zinc Manganese Battery Printing date: 06/06/2020
-- Page 3 / 7 --
6. Accidental release measures
(a) Personal precautions, protective equipment and emergency procedures
No action shall be taken involving any personal risk or without suitable training. Review Section 5 and Section 7
sections before proceeding with clean-up. Use proper personal protective equipment as indicated in Section 8.
Appropriate ventilation. If electrolyte leaks or spills, do not touch or walk through electrolyte.
(b) Methods and materials for containment and cleaning up
Remove all sources of ignition or heat. Stop leak if safe to do so. Move containers from spill area. Carefully collect
undamaged batteries in a clean, dry and appropriate container for reuse or disposal. If electrolyte leaks or spills,
collect all released material in an appropriate container before proper disposal.
7. Handling and storage
(a) Precautions for safe handling
Do not dispose in fire, mix with other battery types, charge above specified rate, connect improperly, or short circuit,
which may result in overheating, explosion or leakage of cell contents. Accidental short circuit will bring high
temperature elevation to the battery as well as shorten the battery life. Be sure to avoid prolonged short circuit since
the heat can burn attendant skin and even rupture of the battery cell case. Battery bulk container, coins, metal
jewelry, metal work table, metal belt or other equipment for assembly battery may be the source for short circuit.
Use effective anti short circuit measures. Do not use organic solvents or other chemical cleaners on battery. Do not
disassembly or decompose. Avoid contacting with water, avoid straight sunlight.
(b) Conditions for safe storage, including any incompatibilities
Store in a cool, well ventilated area. Elevated temperatures can result in shortened battery life.
8. Exposure controls/personal protection
(a) Control parameters
Zinc
N/A
MANGANESE (COMPOUNDS AND DUST), as Mn
NIOSH REL: TWA 1 mg/m
3
; ST 3 mg/m
3
OSHA PEL-C: 5 mg/m
3
Graphite
N/A
IRON SALTS, SOLUBLE, as Fe
NIOSH REL-TWA: 1 mg/m
3
Potassium hydroxide
NIOSH REL-C: 2 mg/m
3
(b) Appropriate engineering controls
General room ventilation is sufficient during normal use and handing. Do not install these batteries in sealed,
unventilated areas. Facilities storing or utilizing this material should be equipped with an eyewash facility and a
safety shower.
(c) Personal protective equipment
Respiratory protection:
Not necessary under normal conditions.
Hand protection:
Not necessary under normal conditions. Use neoprene or natural rubber gloves if
handing an open or leaking battery.