Single Zone Outdoor Condenser Installation Manual

DURASTAR.COM
10
OUTDOOR UNIT INSTALLATION
Installation Instructions
Install the unit following local codes and regulations. These may differ slightly between regions.
STEP 1: SELECT INSTALLATION LOCATION
Before installing the outdoor unit, you must choose an appropriate location. The following are
standards that will help you choose an appropriate location for the unit.
Proper installation locations meet the following standards:
Meets all spatial requirements shown in installation space requirements above.
Good air circulation and ventilation.
Firm and solid location —the location can support the unit's weight and will not vibrate.
Noise from the unit will not disturb others.
Protected from prolonged periods of direct sunlight or rain.
Where snowfall is anticipated, raise the unit above the base pad to prevent ice buildup and coil
damage. Mount the unit high enough to be above the average accumulated area snowfall. The
minimum height must be 18 inches.
DO NOT install unit in the following locations:
Near an obstacle that will block air inlets and outlets.
Near a public street, crowded areas, or where noise from the unit will disturb others.
Near animals or plants that will be harmed by hot air discharge.
Near any source of combustible gas.
In a location that is exposed to large amounts of dust.
In a location exposed to an excessive amount of salty air.
24” (610)
on right
12” (305)
on left
79” (2007)
in front
12” (305)
from back wall
24” (610)
above