DRA4U36M1A Submittal

1 Form No. V1.0_02.21
Specifications are subject to change without notice.
© 2021 Ferguson Enterprises LLC
www.durastar.com
36,000 BTU/H MULTI-ZONE HEAT PUMP SYSTEM
Multi-Zone Outdoor Unit (ODU):
DRA4U36M1A
PROJECT NAME
LOCATION
ARCHITECT
ENGINEER
CONTRACTOR
REFERENCE
SUBMITTED BY DATE
SUBMITTAL COVER SHEET
EFFICIENCY DATA
DUCTLESS DUCTED
SEER 22.5 21.0
EER 10.9 10.0
HSPF 10.3 10.0
CAPACITIES
DUCTLESS DUCTED
Cooling Capacity
(BTU/hr)
Rated
1
36000 30000
Minimum 10800 9900
Maximum 38800 38000
Heating Capacity
(BTU/hr)
Rated
2
36000 30000
Minimum 11000 7600
Maximum 37900 43000
OUTDOOR TEMPERATURE OPERATION
Cooling -13 °F - 122 °F
(-25 °C - 50 °C)
Heating -13 °F - 86 °F
(-25 °C - 30 °C)
ELECTRICAL DATA
DUCTLESS DUCTED
Voltage/Phase/Frequency
208-230V, 1 Phase, 60 Hz
Voltage Range 187-253V
Recommended Breaker (Amps) 45
Minimum Circuit Ampacity (Amps) 30
Minimum Wire Size 16 AWG
Rated Current - Cooling (Amps)
1
13.6 15.7
Rated Current - Heating (Amps)
2
13.5 13.2
1
Measured at 95 °F.
2
Measured at 47 °F.
PRODUCT FEATURES
Variable Speed Inverter Compressor
Included Base Pan Heater
Auto Restart