INDOOR UNIT INSTALLATION
STEP 1: SELECT INSTALLATION LOCATION
Before installing the indoor unit, you must choose an appropriate location. The following
standards must be met for an appropriate location for the unit:
Good air circulation
Convenient drainage
Noise from the unit will not disturb other people
Firm and solid - the location will not vibrate
Strong enough to support the weight of the unit
A location at least three feet (one meter) from all other electrical devices (e.g., TV, radio,
computer)
DO NOT install unit in the following locations:
Near any source of heat, steam, or combustible gas
Near flammable items such as curtains or clothing
Near any obstacle that might block air circulation
Near a doorway
In a location subject to direct sunlight
Refer to the following diagram to ensure proper distance from walls and ceiling:
4 3/4” (12cm)
or more
6’ (1.83m) or more
4 3/4” (12cm)
or more
6” (15cm) or more
NOTE
If there is no pre-existing refrigerant piping, when choosing a location, leave ample room
for a wall hole (see Step 3: Drill Wall Hole for Connective Piping) for the signal cable and
refrigerant piping that connect the indoor and outdoor units. The default position for
all piping is the right side of the indoor unit (while facing the unit). However, the unit can
accommodate piping to either the left or right.