Slim Ducted Installation Manual

DURASTAR.COM
12
INDOOR UNIT INSTALLATION
STEP 1: SELECT INSTALLATION LOCATION
Before installing the indoor unit, you must choose an appropriate location. The following standards
should be met for an appropriate location for the unit:
Good air circulation
Convenient drainage
Noise from the unit will not disturb other people
Firm and solid - the location will not vibrate
Strong enough to support the weight of the unit
A location at least three feet (one meter) from all other electrical devices (e.g., TV, radio, computer)
DO NOT install unit in the following locations:
Near any source of heat, steam, or combustible gas
Near flammable items such as curtains or clothing
Near any obstacle that might block air circulation
Near a doorway
In a location subject to direct sunlight
Refer to the following diagrams to ensure proper distance from walls and ceiling:
NOTE
If there is no pre-existing refrigerant piping, when choosing a location, leave ample room
for a wall hole (see Step 3: Drill Wall Hole for Connective Piping) for the signal cable and
refrigerant piping that connect the indoor and outdoor units.
Maintenance access panel
Installation clearances
Left
side
Right
side
Strong and durable ceiling
Indoor unit
>7 7/8”(200mm) >11 13/16”(300mm)
>13/16”(20mm)
>11 13/16”(300mm)
>90 9/16”(230cm)
Floor
Service access Ceiling
Air outlet
Air inlet
24” x 24”(610mm x 610mm)
Maintenance access panel
>13/16”(20mm)
>7 7/8”(200mm)
>11 13/16”(300mm)
B