Installation

6


 
10"

12"

14"

16"

pass through oors of buildings requiring
the protection of vertical openings shall be
enclosed with approved walls having a re
resistance rating of not less than one hour
when such chimneys are located in a building
less than 4 stories in height, and not less than
2 hours when such chimneys are located in a
building more than 4 stories in height.”
In Canada, except in single-family and two-
family dwellings, chimneys which extend
through another story must have an enclosure
with a re resistance rating equal to or greater
than that of the oor or roof assembly through
which they pass.
 In cold climates, chimneys
mounted on an outside wall should be
enclosed in a chase. Exterior chases reduce
condensation and creosote formation, and
enhance draft. Always maintain a 2” air-space
clearance to combustibles.

Always follow the replace manufacturer’s
installation instructions.
 Install your replace as described
by the replace manufacturer. Be sure to
maintain all required clearances.
 Connect only one replace per chimney.
Operation: Follow the replace safety manual
for maximum efciency and safety. Do not over
re. Any damage to the replace or chimney can
possibly void your warranties.
 Do not burn driftwood, plastic, or
chemically treated wood such as railroad ties.
They are corrosive to your chimney system.
Follow the replace manufacturers instructions
regarding fuels.


 Position the replace
MASONRY
ANCHORS
HI-TEMP
SEALANT
ANCHOR PLATE
OR ANCHOR PLATE
WITH DAMPER
Figure 2
Figure 3
ANCHOR PLATE
WITH DAMPER
NOTE: DAMPER PLATE
IS CLOSED WHEN
CHAIN IS HOOKED
ON LINTEL HOOK
LINTEL
HOOK