Planning Your Installation
The following recommendations are general guideline to assist in the 
layout and selection of the chimney components needed for your 
installation. Always follow DuraVent Installation instructions before 
installing your chimney system, found with the cap or support box. 
Installation instructions can be viewed online at www.duravent.com, 
under catalogs and instructions.
• The diameter of the chimney should match the outlet size of the 
appliance. An improperly sized chimney results in poor draft and 
excessive creosote formation.
• Measure the diameter of the appliance ue outlet. Select the 
chimney and either DVL or DuraBlack connector stovepipe with 
the same size diameter as the appliance ue outlet. For replace 
installations, refer to the sizing chart in the back of this catalog.
• Determine if the installation is a through-the-roof installation or 
a through-the-wall installation. A through-the-wall installation will 
require additional components (Wall Thimble, Tee/ Cap, Tee Support, 
and Wall Straps). 
• Install the chimney in the interior of the structure whenever 
possible. A cold exterior chimney will produce less draft and will 
generate more creosote.
• If possible avoid osets that serve to restrict the natural draft. A 
straight vertical installation is more ecient and less likely to develop 
creosote. If an oset is required to avoid rafters or other obstructions, 
measure the horizontal distance required and the vertical height 
available. Both 15° and 30° elbows are available. Elbows have a 360° 
swivel base to allow orientation of elbow direction only. Elbows are 
xed at 15° or 30°. Elbows greater than 30° are not allowed in the 
United States. A maximum of two osets in a single installation are 
permitted. Refer to the oset table in the back section of this catalog. 
At least one Elbow Strap is required for each oset. Elbow Straps 
ensure adequate support. 
• Determine the minimum chimney height above the roof line. 
Building codes require a minimum of 3’ above the roof penetration 
and at least 2’ higher than any portion of a building within 10’. See 
gure 1. The termination cap is installed above that point. If chimney 
extends 5’ or more above the roof penetration an extended roof 
bracket is required. An additional roof bracket is needed every 5’.
• Measure the roof pitch. For example a 6/12 pitch has a vertical rise of 
6” over a horizontal distance of 12”. Select the appropriate ashing.
• Determine the total length of chimney and stovepipe required for 
the installation. To calculate the installed per length of 5”-8” DuraTech 
pipe, subtract 1 ¼” per joint. For 10”-24” diameter, subtract ¾” per 
joint of pipe. Subtract 1 ¼” per joint of DuraBlack stovepipe. Subtract 
1 ½” per joint of DVL stovepipe. Minimum chimney height, at sea 
level, of straight vertical chimney is 10’ to 15’ above the appliance 
outlet. Higher elevations, or the use of elbows or a tee, will require 
approximately 30% to 60% more height to provide for an 
adequate draft.
• For a UL approved shroud, see the DuraTech Shrouds Installation 
Instructions (L157). View online at www.duravent.com, under catalogs 
and instructions.
• Be re safe. Maintain at least 2” clearance to combustibles. Follow 
local building codes and have your chimney inspected by a 
certied professional.
Figure 1
3 FT. MIN.
ABOVE ROOF
PENETRATION
2 FT. MIN. ABOVE
HIGHEST POINT OF
THE BUILDING WITHIN 10 FT.
MINIMUM CHIMNEY HEIGHT REQUIREMENT