1. Place Appliance: Position the appliance 
according to the manufacturer’s instructions. It 
is a good idea to try to position the appliance 
so it will allow the chimney to line up centered 
between studs.
2. Locate, Cut & Frame Opening: 
Determine the location where the chimney will 
pass through the wall. The chimney should 
pass through the wall, centered between 
two studs. The height of the penetration 
can be determined by positioning sections 
of connector pipe until you have the 
desired conguration (refer to the appliance 
manufacturer’s installation instructions for 
restrictions on connector pipe). Cut and frame 
an opening in the inner and outer walls at this 
location. Refer to Table 2 for the appropriate 
framing dimensions.
3. Install Wall Thimble:  The Wall Thimble is a 
three piece unit which includes the cover plate, 
sleeve extension, and the back portion with 
shield. On the outside wall, install the back 
portion of the Wall Thimble. Center the back 
portion of the Wall Thimble (with shield inside 
wall) in the framed opening of the outside wall.  
Be sure to seal the ange of the Wall Thimble 
around the wall by using a non-hardening 
waterproof sealant. Attach the back portion 
of the Wall Thimble to the outside wall using 
at least (4) 8-penny nails or (4) 1-1/2” wood 
screws (Fig 20). Depending on the thickness 
of your wall, you will need to adjust the shield 
extension to insure that you have a continuous 
shield throughout the wall penetration. 
Adjustments can be made by sliding the 
extension in or out of the back portion of the 
shield. Verify that the shield extension reaches 
the front cover plate when the cover plate is 
in position. Do not install cover plate at this 
time. When the shield extension is in position, 
secure it to the back portion of the shield using 
(4) sheet metal screws (Fig 20).
4. Install Tee Support:  Install the Tee 
Support on the outside wall. Position Tee 
Figure 19
UP
TEE BRANCH
(MUST PENETRATE
A MINIMUM OF 6
INCHES INTO
ROOM)
WALL THIMBLE
ASSEMBLY
FINISHING
COLLAR
CHIMNEY
SECTION
CHIMNEY TEE
1/4"X2" LAG
SCREWS (3
REQUIRED)
TEE CAP
RETAINING BAR
BOLTS FOR
RETAINING BAR
TEE CAP