Installation Guide
18
the masonry ue opening. If a Damper is 
used, make sure nothing interferes with the 
damper plate movement. Seal the Anchor 
Plate in place with a high temperature sealant. 
Secure Anchor Plate with (4) 2” x 1/4” masonry 
anchors (Fig. 24).
3a. Damper Plate: The Damper Plate should 
swing freely once the Anchor Plate is installed. 
When the chain is pulled down, the damper 
plate should close (horizontal position). When 
the chain is released (no weight on the chain), 
the damper should swing open (vertical 
position).
3b. Lintel Hook: With the damper plate in 
the closed (horizontal) position, determine 
and mark the location for the Lintel Hook. The 
Lintel Hook should be mounted in a position 
so as to provide a small amount of tension in 
the spring attached to the chain (Fig. 25). The 
MASONRY FIREPLACE 
INSTALLATIONS 
1. Determine Chimney Size: Use Table 4 to 
determine the correct diameter chimney for 
your replace. 
2. Mount Anchor Plate: Chimneys for 
masonry replaces begin with an Anchor Plate 
or Anchor Plate with Damper. Warning: Anchor 
Plate with Damper is not allowed in chimneys 
serving stoker-red, liquid or gas burning 
appliances. Caution: Do not install Anchor 
Plate with Damper on Factory-built replaces. 
Important: be sure the surface of the masonry 
chimney has a level surface on which to attach 
the Anchor Plate or Anchor Plate. If the top of 
the masonry does not have a level surface, 
then you will need to modify the masonry 
accordingly. Center the Anchor Plate over 
Figure 23
STORM COLLAR SITS DOWN ON COLLAR 
OF CHASE TOP FLASHING. TIGHTEN 
SO THERE IS AT LEAST 1" CLEARANCE 
BETWEEN STORM COLLAR AND 
FLASHING.
3/8 INCH AIR SPACE
ESTABLISHED BY SPACERS
3/8 INCH
AIR
SPACE
6 INCH MINIMUM
CLEARANCE
BETWEEN BOTTOM
OF CAP AND CHASE
TOP FLASHING
FRAMED CHASE
ENCLOSURE
CHIMNEY
CAP
STORM
COLLAR
CHASE TOP
FLASHING
CHIMNEY
SECTIONS
CHASE TOP
FLASHING SPACER
3/8 INCH
3/8 INCH