Installation Guide

13
M&G DURAVENT
POLYPRO
CHIMNEY CAP
TERMINATION
COMBUSTION
AIR INTAKE
FLEX HANGER
BRACKET AND
HARDWARE
AIR INTAKE
FLEX
FLEX CLAMP
M&G DURAVENT
POLYPRO
EXHAUST SYSTEM
STORM COLLAR
ENCLOSURE
M&G DURAVENT
POLYPRO
EXHAUST SYSTEM
AIR INTAKE
FLEX
AIR INTAKE
FLEX TO
POLYPRO
ADAPTER
POLYPRO PIPE TO
APPLIANCE AIR
INTAKE
ALUM FLEX AIR INTAKE (Fig.23)
Important: This section only applies to
sourcing combustion air!
Reference Fig.23 for installation of air intake
ex when used with the M&G DuraVent
Chimney Cap Termination. Combustion air
is drawn in under the storm collar. Ensure
Aluminum ex is approx 1"-2" below
termination base for unrestricted operation.
See Fig.24 for the lower install.
MAINTENANCE
Have your venting system checked annually.
This can be done easily by the same
technician who inspects & services the
appliance. Recommended areas to inspect
are as follows:
- Check areas of the Venting System which
are exposed to the elements for wear or
damage. If damage is found, the components
should be replaced immediately.
- Where possible, look into the Termination
Cap to verify no foreign material is there to
block the vent. Remove any foreign material
found.
- Where practical, inspect joints to verify
that no Pipe Sections or Fittings have been
disturbed, and consequently loosened. Also
check mechanical supports such as Wall
Straps, support plates, etc for rigidity.
Figure 23- Upper Assy
Figure 24- Lower Assy
Figure 22
HANGER
MOUNTED
TO TOP OF
SUPPORT,
BELOW
GASKET
PLATE
SEAL AS
REQ'D