Submittal

18
Figure 11
POSITIONED
HORIZONTALLY
POSITIONED
VERTICALLY
AIR INLET PIPE
OUTER COVER PLATE
APPLY BEAD OF SILICON SEALANT
AROUND FEMALE END OF PIPE TO
SEAL AGAINST EXTERIOR WALL PLATE
INTERIOR
WALL PLATE
EXTERIOR WALL PLATE
EXHAUST TIP
EXHAUST PIPE
Figure 10
REMOVE GASKET
INSERT BIRD GUARD
Figure 9
ALIGN TABS WITH
MOUNTS
GASKET
EXTERIOR
WALL PLATE
INTERIOR
WALL PLATE
TERMINATIONS:
Horizontal Single Pipe (Fig.9)
1. Locate penetration in wall.
2. Cut or cut and frame hole. (Table 3)
3. Attach Inner Plate to wall.
4. Attach / seal Outer Plate to outside wall.
5. Line up keyway, slide black pipe (UV Protected) or
termination through plates.
6. If termination is used, attach with screws. Align tabs
with pipe mounts.
7. Add additional components to raise vent level if desired
(vent to be 12” above grade or average snow level).
8. Remove gasket and install Bird Guard into end of pipe.
(Fig.10)
9. Install Poly Pro venting system to/from termination to
appliance.