Install Instructions
Figure 3a
LOCKING
TAB
LOCKING
BAND RECESS
1/4"
CLICK!
LOCKING
BAND CLASP
VERIFY GASKET IS 
SEATED IN FEMALE 
END OF PIPE
Figure 3b
NEW 
LOCKING 
CLAMP
TIGHTEN HOSE 
CLAMP TO SECURE
JOINT
VERIFY LOCKING 
CLAMP HOOKS
UNDER GASKET
EXTRUSION
POLYPRO SINGLEWALL
JOINT CONNECTIONS
Locking Band (Old Design): Verify the 
gasket is seated evenly inside the groove in 
the female end of the pipe.  For PP / Metal 
pipe with a locking tab, slide the Locking 
Band on to the male pipe section Fig.3a. 
Insert locking tab into locking band recess, 
rotate button away from locking band clasp, 
insert pipe sections, push lock band clasp 
downward over the socket, disengage tab 
1/4"-5/8" from socket. 
Locking Clamp (New Design): Verify the 
gasket is seated evenly inside the groove 
in the female end. Assemble the joint by 
passing the male end of the Polypro Pipe 
through the Locking Clamp on the hose 
clamp side and into the female end of the 
PolyPro pipe, (Fig.3b). Hook the Locking 
Clamp onto the gasket extrusion on the 
female end and tighten down on the hose 
clamp.
The new Locking Clamp design is 
backwards compatible with pipe sections 
designed for use with the Locking Band. 
Use pliers to break o the Locking Tab with 
a twisting motion. Once removed, install 
the pipe section following the Locking 
Clamp instructions. Locking Clamps can be 
purchased separately in packs of 12. 
Fig.3a and b. Screws are not allowed for 
joint connection. Never penetrate the 
wall of PolyPro Single-Wall vent pipe. 
(Exception: a stainless steel screw may 
be used outside the building on exterior 
termination ttings to orient an elbow, 
etc).
•  IMPORTANT: Locking Bands or Locking 
Clamps are mandatory on all exhaust 
vent joints
POLYPRO TO DURAVENT / SECURITY 
CHIMNEY METAL VENT CONNECTION
To transition from PolyPro to Duravent / 
Security metal vents that are UL 1738 or ULC 
636 listed, an approved adapter must be used. 
Installation of PolyPro (female) to metal vent 
adapter (male) is the same process as illustrated 
in Fig.3a and b. 
7