PolyPro Installation Manual

10
of the house, and rest between the two
outward beads.
2. Install the termination assembly
in accordance with appliance
manufacturers instructions.
3. Verify exhaust pipe cannot be removed
from termination cap.
Lochinvar / IPEX twin plate termination
connector- 3" & 4" installation (Fig.14)
1. Slide PolyPro Pipe w/ PVC adapter into
small hole of retaining plate until it stops
on the adapter collar.
Figure 14
POLYPRO PIPE
W/PVC ADAPTER
SUPPLIED WITH
TERMINATION KIT
Figure 13
BRACKET
POLYPRO PIPE
W/PVC ADAPTER
SUPPLIED WITH
TERMINATION KIT
Figure 12
SCREW TO
TERMINATION
AIR INTAKE
EXHAUST
COLINEAR
ADAPTER
INSTALL
GASKETS
EXTERIOR
WALL PLATE
INTERIOR
WALL PLATE
HORIZONTAL
TERMINATION
Horizontal Concentric (Fig.12)
1. Locate penetration.
2. Cut hole. (Table 3)
3. Attach and seal exterior exterior wall
plate onto outside wall.
4. Slide cap through exterior wall plate into
hole from outside building. Cap must
not be installed sloped downward.
5. Orient termination so air intake slots
face down.
6. Seal termination to exterior wall plate
with silicone sealant.
7. Slide interior wall plate over termination
and attach to wall from inside the room.
8. Attach interior wall plate to termination
with provided hardware.
9. Install gaskets into Co-Linear Adapter.
10. Attach Co-Linear Adapter to Horizontal
Termination.
11. Install Poly Pro venting system to/from
termination to appliance.
Lochinvar / IPEX twin plate termination
connector- 2" installation (Fig.13)
1. Slide PolyPro pipe w/ PVC adapter into
oblong hole and down. Brackets will
point away from the wall, on the exterior
2. Finish installing the termination
assembly in accordance with appliance
manufacturers instructions. PolyPro
pipe is to be installed on the exhaust
outlet.
3. Once securely installed to exterior, verify
exhaust pipe cannot be removed from
termination cap.