Install Instructions

Figure 2
PUSH DOWN
TO LOCK
PRY OUT
TO UNLOCK
VERIFY GASKET IS
SEATED IN FEMALE
END OF PIPE
MALE
END
FEMALE
END
Figure 3
APPLIANCE CONNECTION: 2" - 4"
1. If the appliance has a PVC/CPVC female
outlet use the Appliance Adapter/ PVC
Adapter and Clamp. (Fig.4)
If the appliance has a PVC/CPVC
Male outlet use a matching PVC/
CPVC coupling to convert to a
female outlet.
2. If the appliance outlet has a rubber
boot or Fernco-style appliance adapter,
then the PolyPro vent pipe may attach
directly to the appliance (Fig.5).
3. If the appliance has a FasNSeal outlet
then use the FasNSeal to PolyPro
adapter.
6
Figure 5
APPLIANCE
OUTLET
POLYPRO
VENT PIPE
TIGHTEN CLAMPS ON
RUBBER COUPLER
ADAPTER OR FERNCO
STYLE ADAPTER TO
SECURE VENT
PIPE TO APPLIANCE
mandatory on all exhaust vent joints
on pipe sizes from 2" up to 4". (Fig.2, 3)
For 5"-8" diameter, Locking Bands are
not required but strongly recommended
at every exhaust vent joint.
(Fig.2, 3)
Locking bands are optional for air inlet
vent joints.
(Fig.2, 3)
POLYPRO TO DURAVENT / SECURITY
CHIMNEY METAL VENT CONNECTION
Approved M&G Duravent / Security Chimney
1738/636 metal vent ttings can be used with
PolyPro. For PolyPro (female) to Metal Vent
(Male) connections, the metal ttings will have
a Locking Button or Protrusion, and will be
connected simliar to Fig. 3.
LOCKING BAND
Figure 4
POLYPRO PIPE
APPLIANCE
ADAPTER CLAMP
APPLIANCE ADAPTER/
PVC ADAPTER
APPLIANCE
EXHAUST OUTLET
OR PVC UNION
APPLIANCE
LOCKING
BUTTON
LOCKING
BAND RECESS
1/4"
CLICK!
LOCKING
BAND CLASP