Installation Guide
16
4. Complete Installation: Refer to Steps 8, 
and 9, in the Ceiling Supported Installation 
section, to complete the Roof-Supported 
installation. 
TEE-SUPPORTED INSTALLATIONS 
Tee-Supported installations are used when 
passing through a wall to an outside chimney. 
The required parts and general conguration 
are as shown in Figures 23, and 24. 
1. Place Appliance: Position the appliance 
according to the manufacturer’s instructions. 
2. Cut and Frame Opening: Cut 
14-1/4 inch diameter holes in the inner and 
outer walls. The center of these holes should 
be aligned with the center of the stove’s ue 
outlet collar. For new construction, prior to 
sheetrock or other covering of the wall studs is 
applied, frame a square opening between the 
studs, as specied in Table 2. ( Figure 25). 
Should it be necessary to go through concrete, 
masonry, or cinder-block, a 14-1/4 inch 
Figure 25
14 1/2”
14 1/2”
Figure 24
PIPE SECTION 
6-INCH OR 9-INCH
SDP-P
WALL THIMBLE
SDP-WT
PIPE
SDP-P
TEE
SDP-T
TEE SUPPORT
SDP-TS
TEE CAP 
(COMPONENT OF 
SDP-T)
TEE CAP 
COMPONENT OF 
SDP-T
REMOVABLE 
TRAY 
(COMPONENT 
OF SDP-TS)
5/16 X 3” LAG 
SCREWS 
(6 REQ) NOT 
FURNISHED
Figure 23
WARNING: 
VENTILATED 
FLASHING MUST 
BE USED WITH 
ENCLOSURES.
ALLOW 1/2 INCH AIR 
SPACE BETWEEN BASE 
OF FLASHING OR COVER 
AND ENCLOSURE 
FRAMING.
TYPICAL 
THRU-THE-WALL 
TEE- SUPPORTED 
INSTALLATION
ACCESS DOOR 
FOR CLEANING
FRAMED 
EXTERIOR 
ENCLOSURE