Installation Guide
21
ZERO-CLEARANCE FIREPLACE 
INSTALLATIONS 
1. Manufacturer’s Instructions: Carefully 
read and comply with the manufacturer’s 
installation instructions for your replace. Verify 
that DuraVent’s DuraPlus chimney is approved 
for use on your replace.
2. Base Plate: Attach a Base Plate to the 
replace top with sheet metal screws. (Figure 
31). A high temperature sealant may be used 
if desired. 
3. Chimney Sections: Attach a Chimney 
Section to the Base Plate by twist-locking. 
4. Completion: Install the remainder as 
instructed for a standard Ceiling-Supported 
installation, (less the Support Box). Always 
maintain at least 2 inches of clearance to 
combustibles, and enclose the chimney where 
it passes through occupied areas. 
CONNECTION FROM APPLIANCE 
TO CHIMNEY SYSTEM
1. Single Wall Stovepipe: DuraVent’s 
“DuraBlack” stovepipe is recommended, 
if single wall stovepipe is desired. The 
connection to the ceiling support box, or 
wall thimble is made with a DuraBlack Slip 
Connector (Part# 1670, 1770, or 1870, for 
6-inch, 7-inch, or 8-inch pipe, respectively). 
The beaded end of the slip connector slips into 
the hole in the ceiling support or wall thimble. 
Align the tabs on the slip connector with the 
notches in the face of the support or wall 
thimble, push the connector in, and twist to 
lock it in. Further instructions for assembling 
the DuraBlack pipe are contained in their 
shipping cartons. Remember, the minimum 
clearance to combustibles for single wall 
stovepipe is 18 inches.
2. DVL:  DuraVent manufactures DVL, which 
is a double-wall connector pipe, which may 
be positioned within 6 inches to a combustible 
wall, and within 8 inches to a combustible 
ceiling, provided the appliance installation 
instructions permit this distance. In order 
to join this type of connector to the ceiling 
support, or wall thimble, a Close Clearance 
Adaptor (Part #8674, 8774, or 8874, for 
6-inch, 7-inch, or 8-inch pipe, respectively), 
is required. The adaptor slips into the hole in 
the ceiling support, or wall thimble. Align the 
tabs on the adaptor with the slots cut into the 
face of the ceiling support, or wall thimble, 
push in, and twist to lock it in place. Detailed 
instructions for assembling the remainder of 
the close clearance system are included in the 
shipping cartons. 
Figure 31
CHIMNEY 
SECTION
SHEET 
METAL 
SCREWS
BASE PLATE
(SDP-BP)
ZERO-CLEARANCE FIREPLACE