Installation Guide
13
least (2) 8-penny nails or (2) #8, 1-1/2 screws.  
Do not add more Chimney Sections until 
the Elbows are supported. Be sure that the 
chimney remains vertical. If there is more than 
one Chimney Section between the Elbows, 
install a second Elbow Strap around the joint of 
the two Chimney Sections (Fig 15). 
EXTENDED ROOF BRACKET 
INSTALLATION 
If the chimney extends more than 5 feet 
above the rooine, an Extended Roof Bracket 
must be installed at every 5-foot increment 
of chimney height above the rooine, leaving 
no more than 5 feet of chimney extending 
above the last pipe bracket. The Extended 
Roof Bracket consists of the Pipe Band, the 
Adjustable Legs, and the Roof Brackets.
1. Mount Pipe Band: Slip the Pipe Band 
around the chimney and secure by tightening 
the nut and bolt. 
2. Attach the Legs: The Adjustable Legs 
of the assembly will adjust from 67” to 114”. 
Secure one end of each Leg to the Pipe Band 
using the nuts and bolts included (2 per Leg). 
Position the Adjustable legs so they form 
approximately a 60° angle with the chimney, 
and with each other (Figures 16 and 17). Be 
sure that there is at least 3” of overlap between 
the top and bottom halves of the Adjustable 
Leg. In order to secure Legs in proper 
position, there is a hole provided in the outer 
leg where the outer and inner halves overlap. 
Use a 1/4” drill bit to drill through the inner leg 
at that location. Use the nut & bolt provided to 
pin the Adjustable Legs in position. 
3. Install Roof Brackets:  Mount the two 
Roof Brackets where each of the Adjustable 
Legs meets the roof, using (4) 1” roong nails 
or screws per bracket. Seal the nail heads 
carefully with a non-hardening, waterproof 
sealant. Attach the bottom end of the 
Adjustable Legs to the Roof Brackets using the 
nuts & bolts provided. 
ROOF SUPPORTED 
INSTALLATIONS 
There are two types of Roof Supported 
Installations: (1) Using a Square Ceiling 
Support Box, Reduced Clearance Support 
Box, or CAS Ceiling Support; and (2) Using a 
Roof Support. 
(1) For a Square Ceiling Support Box, 
Reduced Clearance Support Box, or CAS 
Ceiling Support installation, make sure that 
the square box portion of the Support Box can 
extend at least 2” below the low side of the 
nished ceiling (Fig 19). If the CAS Ceiling 
Support is used, refer to the DuraTech CAS 
Figure 16
Figure 17
PIPE BAND 
AROUND 
CHIMNEY 
SECTION
ADJUSTABLE 
LEGS ADJUST 
FROM 67 TO 
114 INCHES
EXTENDED ROOF 
BRACKET ASSEMBLY
CHIMNEY CAP
EXTENDED ROOF 
BRACKET
ADJUSTABLE LEGS
MUST USE EXT. 
ROOF BRACKET IF 
OVER 5 FT