Installation Guide
21
gap is maintained between the ashing and the 
chase. Seal the screw heads with non-hardening 
sealant. When installing the Storm Collar, allow 
a 1” air space between the bottom of the Storm 
Collar and the Chase Top Flashing .
MASONRY FIREPLACE 
INSTALLATIONS 
1.  Determine Chimney Size: Use Table 4 to 
determine the correct diameter chimney for your 
replace. 
2.  Mount Anchor Plate: Chimneys for masonry 
replaces begin with an Anchor Plate. Make 
sure the surface of the masonry chimney has 
a level surface on which to attach the Anchor 
Plate.  If the top of the masonry does not have 
a level surface, then you will need to modify the 
masonry accordingly. Follow the requirements 
of your local building department for connecting 
factory-built chimneys to masonry reboxes or 
masonry chimneys. Center the Anchor Plate 
over the masonry ue opening, and seal the 
Anchor Plate with a high-temperature (1000ºF) 
sealant. Secure Anchor Plate with at least (4) 
1/4” x 4” masonry anchors (Fig 30). It is very 
important that the Anchor Plate is level. Be sure 
to maintain a 1” min. clearance to combustibles 
from the Anchor Plate.
3.  Attach Chimney:  Twist lock the rst 
Chimney Section clockwise onto the Anchor 
Plate.  
4.  Finish Chimney:  Install the rest of the 
chimney as directed in the Ceiling Supported 
Installation section, Steps 4 through 10 
Refer to Figure 1 and Table 4 for chimney 
height requirements. Always maintain at least 
2 inches of clearance to combustible materials, 
and enclose the chimney where it passes 
through occupied areas.  Use a Wall Strap for 
every eight (8) feet of chimney height.  
Table 4
T
W
H
and 30” high, and the chimney height as 20’.
12” diameter pipe.
Dotted line represents sample problem.
CHIMNEY SIZING CHART 
FOR FIREPLACE INSTALLATIONS
T
W
H
T
H
8
7
6
30
16
14
20
8
10
15
12
10
50
40
30
24
48
60
36
42
72
HEIGHT
36
30
42
24
48
18
WIDTH
18
20
22
24
20
18
60
72
84
84
HEIGHT
(FEET)
CHIMNEY
FIREPLACE
OPENING (INCHES)
CHIMNEY 
PIPE
DIAMETER 
(INCHES)