User guide
12
available in both 1-piece and 
4-piece versions.
Center the counter ashing on 
the wall around the framed penetration. 
Secure to the wall using the screws 
provided or other necessary connector 
depending on the wall material. Attach 
the Horizontal Cap to the Counter 
Flashing by lining up the holes in the 
cap with the holes in the Counter 
Flashing. Secure using the 4 long 
screws provided with the cap (Fig. 12). 
Attach the 4 pieces together 
starting with the top piece and work 
counter-clockwise. 
 Secure the 4 pieces together before 
mounting Counter Flashing to the wall. 
Mount the assembled Counter Flashing 
on the wall, centered around the framed 
wall penetration. 
 Depending on wall construction, use 
screws or other suitable connector 
through the anged edges to secure 
Counter Flashing to the wall. 
 Seal around the perimeter of the 
Counter Flashing using non-hardening 
waterproof sealant to help ensure a 
weather tight seal.
 If the optional copper version of 
Horizontal Termination Cap is installed, 
use an appropriate non-combustible 
material to avoid direct contact between 
the galvanized and copper metals to 
prevent possible galvanic reaction.
Step 1. Check the appliance 
manufacturer’s installation instructions 
for required clearances (air spaces) to 
combustibles when passing through 
CUT EXTERIOR
OF WALL AS
REQUIRED IN
ASSEMBLE VINYL
STANDOFF/COUNTER
SPECIFIC ORDER 
TABLE 1 
FLASHING IN
VINYL SIDING,
STUCCO OR OTHER
SIDING MATERIAL
1
2
3
4
HOT
HOT
HOT
4 PC. KIT
ASSEMBLED IN
SEQUENCIAL 
ORDER 
 FASTEN THE 
4 CORNERS 
THROUGH 
THE HOLES
 PROVIDED
FASTEN TERMINATION
TO ASSEMBLY
THROUGH THE 
HOLES PROVIDED
SQUARE
ROUND
CAP
SCONCE
CAP
CAP
1st
2nd
3rd
4th
HOT
PLUMB AND LEVEL
ENSURE ASSEMBLY IS
 GAPS 
& SCREWS
SEAL ALL
CONNECT TO WALL
AS REQUIRED