User guide
18
Sections. Continue to add Pipe 
Sections until you are above 
the rooine.
Step 8.  Follow Steps 7 through 
10 (page 15 & 16) of the Vertical 
Installation Instructions.
Step 9. Install the black Trim Collar 
around the outside of the Cathedral 
Ceiling Support Box. The two pieces 
of the Trim Collar slide over one 
another to allow for easy adjustment 
around the Support Box. Using the six 
(6) screws provided, secure the four 
corners and the overlapping sections 
of the Trim Collar to the underside of 
ceiling. You may want to pre-drill the 
holes for the overlapped sections for 
ease of installation (Fig. 22).
Conduct an inspection of the venting 
system annually. Recommended 
areas to inspect are as follows:
. Check areas of the Venting System 
which are exposed to the elements 
for corrosion. These will appear as 
rust spots or streaks, and in extreme 
cases, holes. These component 
should immediately be replaced. 
 Remove the Vertical Termination 
Cap and shine a ashlight down the 
Vent. Remove any bird nests, or other 
foreign material. 
 Check for evidences of excessive 
condensation, such as water 
droplets forming in the inner liner, 
and subsequently dripping at joints. 
Continuous condensate can cause 
corrosion of caps, pipe, and ttings. It 
may be caused by having excessive 
lateral runs, too many elbows, and 
exterior portions of the system being 
exposed to cold weather.
. Inspect joints to verify that no 
Pipe Sections or Fittings have been 
disturbed or loosened. Also check 
mechanical supports such as Wall 
Straps or plumbers tape for rigidity.
All components are 
labeled with the appropriate 
identication information, and the UL 
listing data, where applicable.
When installing DirectVent Pro on 
appliances in Canada, a 2-piece Wall 
Thimble is required in order to comply 
with IR #41 (Fig. 23 and Fig. 24). Cut 
and frame an opening in the wall in 
accordance with the dimensions in 
Table 1, page 8. Install galvanized 
exterior Wall Thimble plate on exterior 
of building and the other half of the 
Wall Thimble on the interior side of 
wall. Install Wall Thimble centered 
through a square framed opening in 
wall. Install a Wall Thimble Cover on 
the wall to cover the inside portion of 
the Wall Thimble. Be sure to maintain 
all minimum clearances specied 
by appliance manufacturer. When 
installing DirectVent Pro vertically 
through oors (Fig. 25) a Ceiling 
Firestop is required at every oor/
ceiling level. Refer to appliance 
manufacturer installation instructions 
for complete installation procedure.